64
64
Auto Seat Open Function
Symptom
Cause
Solution
Page
The seat and
lid closes too
quickly.
The seat and lid are pushed
during auto close.
Press the Open/Close button.
If the seat does not open or
close automatically, disconnect
the power plug from the outlet
and contact our company for
service.
—
The lid does not
open or close
automatically.
The Auto Seat Open button is
turned off.
Turn on the Auto Seat Open
button.
17
The commercial toilet lid cover
and/or seat cover is too heavy
or is caught somewhere.
Remove the toilet seat lid cover
and/or seat cover.
—
The toilet seat lid is not
assembled correctly.
Assemble the toilet seat lid
correctly.
42
The toilet seat lid was closed
manually or with the remote
control.
The toilet seat lid does not open
automatically for approximately
10 seconds after it is closed
manually or with the remote
control.
—
The upper body sensor is
blocked or dirty.
Clean the sensor or remove any
item that may be blocking the
sensor.
34
The seat and lid
open and close
repeatedly even
though no one is
near the toilet.
The seat sensor is dirty.
Clean the sensor or remove any
item that may be blocking the
sensor.
34
The sensor is exposed to direct
sunlight.
Do not expose the sensor to
direct sunlight.
—
The toilet seat
and seat lid
remain open.
The upper body sensor is
blocked or dirty.
Clean the sensor or remove any
item that may be blocking the
sensor.
34
Troubleshooting