Figure 2: RLS-2 Configured to Switch 4 Antennas

 

 
  

 

Notes: 

 

Uses single coax run from each 

RLS-2

 

 

Uses voltage on the feedline to switch the 

RLS-2

 

RLS-2M

 is a converted 

RLS-2

 that switches when −12 Vdc is applied to feedline, other  

       

RLS-2

s switch normally, giving port selection per table below 

 

Voltage Applied 

to Feedline 

Selected Port 

0 Vdc 

Ant Array 1, Segment A 

+12 Vdc 

Ant Array 1, Segment B 

-12 Vdc 

Ant Array 2, Segment C 

12 Vac 

Ant Array 2, Segment D 

 

 

The 

FVC-1

 applies the voltages to the feedline and can be controlled using BCD logic 

        with the 

CC-8A

 or a switch closure to ground arrangement 

 
The configuration shown in 

Figure 2

 requires a modification to one of the 

DXE-RLS-2

 units to 

operate at -12 Vdc to allow the switching functions shown above. The modification consists of 
removing one diode and installing it backwards as shown below. 

 

 
 
 
 
 
 
 
 
 
 
 

D1 Diode Normal and Reversed 

Summary of Contents for RLS-2

Page 1: ...na Switch RLS 2 DXE RLS 2 INS Revision 3a DX Engineering 2017 1200 Southeast Ave Tallmadge OH 44278 USA Phone 800 777 0703 Tech Support and International 330 572 3200 Fax 330 572 3279 E mail DXEnginee...

Page 2: ...receive antennas Operation The RLS 2 is in effect a SPDT Single Pole Double Throw RF switch that has one input port and two output ports With no control voltage the NC normally closed ANT 1 port is co...

Page 3: ...es when 12 Vdc is applied to feedline DXE RBS 1FP switches when 12 Vdc is applied giving port selection per table below Voltage Applied to Feedline Selected Port 0 Vdc Beverage A Away 12 Vdc Beverage...

Page 4: ...Vdc Ant Array 1 Segment A 12 Vdc Ant Array 1 Segment B 12 Vdc Ant Array 2 Segment C 12 Vac Ant Array 2 Segment D The FVC 1 applies the voltages to the feedline and can be controlled using BCD logic wi...

Page 5: ...r installation Optional Items DXE CC 8A Control Console 8 Position The CC 8A Control Console is a flexible 8 position controller used to control the DX Engineering RR8 series antenna switches the RFS...

Page 6: ...two antenna ports The standard configuration of the RBSA 1P has one port terminated termination included so both antennas share a common feedline Applying negative 10 to 18 Vdc to the feedline switch...

Page 7: ...these connectors DXE CPT 659 Coax Cable Stripper for CATV F 6 RG 6 and RG 59 coax Prepares CATV F 6 RG 6 and RG 59 coax cable for the installation of an F type connector One step cutting motion Precis...

Page 8: ...warranted to be free from defects in material and workmanship for a period of one 1 year from date of shipment DX Engineering s sole obligation under these warranties shall be to issue credit repair...

Reviews: