4
Figure 2: RLS-2 Configured to Switch 4 Antennas
Notes:
Uses single coax run from each
RLS-2
Uses voltage on the feedline to switch the
RLS-2
s
RLS-2M
is a converted
RLS-2
that switches when −12 Vdc is applied to feedline, other
RLS-2
s switch normally, giving port selection per table below
Voltage Applied
to Feedline
Selected Port
0 Vdc
Ant Array 1, Segment A
+12 Vdc
Ant Array 1, Segment B
-12 Vdc
Ant Array 2, Segment C
12 Vac
Ant Array 2, Segment D
The
FVC-1
applies the voltages to the feedline and can be controlled using BCD logic
with the
CC-8A
or a switch closure to ground arrangement
The configuration shown in
Figure 2
requires a modification to one of the
DXE-RLS-2
units to
operate at -12 Vdc to allow the switching functions shown above. The modification consists of
removing one diode and installing it backwards as shown below.
D1 Diode Normal and Reversed