- 17 -
Connect the
RX OUT
jack to a receiver or the transceiver receive-only antenna port.
Do not
connect the RX OUT connector of the NCC-1 to a transceiver RF output!
If desired, connect a fused external power source to the
ANT PWR
2.1
mm center-positive jack if you are not using the
NCC-1
supply to power
antennas (HD4 Jumper Selectable). The allowable voltage range is
+13.8 to +30 Vdc (well filtered & fused) with 300 mA maximum load
current for both INPUTs combined. The DX Engineering
DXE-
ARAH2/V3
Active antennas typically require a nominal 13 Vdc @ 50
mA each. See
Appendix A
for special instructions and a diagram for
remotely powered antennas that r15 to +30 Vdc.