- 5 -
DXE-UHF-FDFB-KIT
SecureMount™ Bulkhead Connector for a clean and quality
feedline connection, one for each Radial Plate
DXE-FP-WIRE-P
Feedpoint Wire & Connector Assemblies, one for each vertical element
DXE- RADW
Radial Wire for the required vertical antenna radials
GCL-1120-050
Copper Radial Cross Bonding Strap, 2” wide
COM-CW3
- Three Wire Control Cable - COM-CW-3 is 3-wire, 20 AWG, stranded copper
with a PVC jacket
Galvanized Mounting Pipe, 1 inch minimum to 2 inches OD maximum, for mounting the
Dual Vertical Array Phasing Relay Unit at the center of the array using the supplied
DXE-
SSVC-2P
Stainless Steel V-Clamp (see text for details)
TES-2155
3M Temflex Tape and
TES-06132
Scotch Super 33 Tape for Weatherproofing
the coaxial cable connections
DXE-400MAX or DXE-213U
or equivalent,
50-ohm coaxial cable for the array main
feedline from the transceiver to the Phasing Relay Unit
Manual Updates
Every effort is made to supply the latest manual revision with each product. Occasionally a manual
will be updated between the time your DX Engineering product is shipped and when you receive it.
Please check the DX Engineering web site (
www.dxengineering.com
) for the latest revision manual.
Tools Required
1/2” nut driver or wrench (for the
DXE-SSVC-2P
V-Clamp)
Wire stripper for control lines
Small flat blade screwdriver for control line connections
Soldering Iron and Solder to join the two radial fields together where they meet
General Installation Information
The DVA Dual Vertical Array Phasing Relay Unit should be mounted to a customer supplied
mounting pipe at the center of the array, halfway between the two monoband verticals.
The DVA Dual Vertical Array Phasing Relay Unit has a built-in, stainless steel, pre-drilled
mounting flange to accommodate up to a 2 inch OD mounting pipe. The included
DXE-SSVC-2P
Stainless Steel V-Bolt Saddle Clamp is for attaching the Phasing Relay Unit to the customer
supplied 1" to 2" OD mounting pipe. An optional
DXE-CAVS-1P
V-Bolt Saddle clamp can be
used for pipe from 3/4" to 1-3/4" inches OD. The Phasing Relay Unit can also be mounted on a
sturdy wooden post.
Note:
JTL-12555
Jet-Lube SS-30 Anti-Seize should be used on all clamps, bolts and stainless steel
threaded hardware to prevent galling and to ensure proper tightening.
The Array Phasing Relay Unit
must
be mounted with cover upward and the control and coaxial
cable connections downward to prevent water from entering the box. The stainless steel base of the
Array Phasing Relay Unit has weep holes to allow condensation that may build up inside the unit to