- 16 -
5. Connect each wire to a terminal (G-1-2) by sliding the wire completely into the wire connection
hole. Using a small flat blade screwdriver, tighten the associated screw until the wire is firmly
gripped in place as shown below.
Terminal 3 is not used
.
Take caution to ensure just the wire is clamped in place, not the wire's insulation which would cause
an open or intermittent connection. Do not over tighten the screw so much that the wire is cut
instead of being firmly gripped. Use the included Ty-Wrap on the inside of the unit to hold the cable
from pulling outward as shown above.
COM-CW3
three wire control cable is a high-quality, PVC-jacketed control cable
consisting of three 20 AWG stranded copper conductors. Your color code may vary.
When connecting the control cable to the DX Engineering Dual Vertical Array system, ensure your
cable is wired the same way at both ends to avoid un-necessary troubleshooting (G to G, 1 to 1 and
2 to 2). Use the chart (below) to record which color wire is connected to each terminal connection.
Connector Wire Reference Chart
G
1
2
The selected position will supply the correct BCD logic voltage as shown in the chart below.
H = +12 Vdc output. Note that with no power, the default selection is Broadside.
Switch Position
OUTPUT
1
2
1
H
BROADSIDE
2
H
The DVA Phasing Relay Unit uses a removable five terminal connector plug as shown below. The
DVA connections are labeled “
G 1 2 3 G
”. The terminals inside the
DXE-EC-DVA
Control
Console use the same connection letters and are connected G to G, 1 to 1 and 2 to 2.
Number 3 is not used and the second G is tied to the first G internally.