Four Square Control Console Rear Panel 
 

 
 
 

                                                                                                                                   Figure 2 

 
 
 
 
 
 
 

 

12 VDC

  

A standard 2.1 mm plug connection for 12 Vdc. The current draw ranges from 30 
mA to 700mA depending on the direction selected. If station power is used, it must 
be 12 Vdc at 1 amp (fused) minimum. An optional 12 Vdc at 1 amp wall 
transformer supply 

DXE-PSW-12D1A

 is available. 

            

Outer connection

 is 

GROUND   

                             

Center Pin 

is input for 

+12 Vdc

.  

 
A 2.1 mm power cord is supplied with unit. The wire with the white stripes is the +12 Vdc. 
 
 
 
 
 
 
 

   

AMP

  

RCA type connector. If you are using a linear amplifier, the keying line should be routed through 
the Four Square Control Console. This jack connects to your amplifier's keying or relay line input. 
The keying signal has essentially no delay on pass through. If you switch antenna positions while 
transmitting, the controller waits until you stop transmitting before switching antennas. Once the 
controller starts to switch antenna relays, amplifier keying signals are inhibited until switching is 
fully completed.  
 
The controller always waits 30 ms before restoring amplifier control signals after any antenna relay 
transfer.  
 
The AMP circuit is capable of switching up to 75 volts open circuit (receiving) and can safely sink 
500 mA maximum current when pulled to ground (transmit). This will handle most modern 
amplifiers. It will not handle high voltage relays, AC relays, or negative voltage keying systems. If 
you have such systems you probably already have a relay line buffer. Simply install that buffer 
between the amplifier and this jack. 

Summary of Contents for DXE-CC-4SQR

Page 1: ...trol Console DXE CC 4SQR DXE CC 4SQR INS Revision 1 DX Engineering 2010 P O Box 1491 Akron OH 44309 1491 Phone 800 777 0703 Tech Support and International 330 572 3200 Fax 330 572 3279 E mail DXEngine...

Page 2: ...been selected All four LEDs are illuminated when OMNI is selected Momentary contact push button switches below each LED select a single direction providing instant switching of directions without rota...

Page 3: ...ast selected direction While in the OMNI mode a new direction may be selected immediately by pushing its corresponding switch The omnidirectional option in the DXE CC 4SQR Control Console is only func...

Page 4: ...ower ON Wait until the first and last LEDs stop blinking 2 Press any two of the pushbutton switches simultaneously and hold them in LEDs will start to blink until the blinking stops The factory defaul...

Page 5: ...ur Square Control Console or you can use the custom label that is included The number one default position on the Transmit Four Square Controller is the first red push button on the left Depending on...

Page 6: ...or relay line input The keying signal has essentially no delay on pass through If you switch antenna positions while transmitting the controller waits until you stop transmitting before switching ante...

Page 7: ...Ground For other systems that usually require a 3 conductor cable we suggest the use of COM CW4 Four Conductor Control Cable four conductor control cable recommended to allow for future upgrade to DX...

Page 8: ...g instructions for return to DX Engineering transportation charges prepaid by Buyer Every such claim for breach of these warranties shall be deemed to be waived by Buyer unless made in writing The abo...

Reviews: