background image

Power ON Relay Exercise 

 
The Transmit Four Square Control Console has a factory default program installed to exercise the 
relays throughout the system when power is turned on. When the unit is properly connected and 
power is turned on, the first and last LED will blink for approximately 6 seconds. While the LEDs 
are blinking, all of the relays in the system are being turned on and off to ensure the relays are kept 
in peak operating performance. During this routine, if any position push button switch is pressed, 
the routine will stop and the system will return to the last position that was selected prior to the 
system being turned off. 
 
The operator can manually turn this routine on or off by pressing a sequence of front panel buttons. 
 
 
 

To turn the factory default OFF: 
 

1.   Turn power ON. Wait until the first and last LEDs stop blinking. 
 
2.   Press any two of the pushbutton switches simultaneously and hold them in (LEDs will start 

to blink) until the blinking stops. The factory default is now turned off. If you turn power 
OFF, wait about 8 seconds (allows internal capacitors to discharge), then turn power ON, the 
system will not run the relay exercise routine. 

 
 
 
 

To turn the factory default ON: 
 

1.   Turn power ON.  
 
2.   Press any two of the pushbutton switches simultaneously and hold them in (LEDs will start 

to blink) until the blinking stops. The factory default is now turned on. If you turn power 
OFF, wait about 8 seconds (allows internal capacitors to discharge), then turn power ON, the 
system will run the relay exercise routine as described above. 

 
 

When the "RADIO" signal is grounded you are in Transmit mode. If you press any of the 
pushbutton switches, they will flash and the unit will not switch positions until you go from 
Transmit to Receive mode. This avoids 'hot switching'. 

Summary of Contents for DXE-CC-4SQR

Page 1: ...trol Console DXE CC 4SQR DXE CC 4SQR INS Revision 1 DX Engineering 2010 P O Box 1491 Akron OH 44309 1491 Phone 800 777 0703 Tech Support and International 330 572 3200 Fax 330 572 3279 E mail DXEngine...

Page 2: ...been selected All four LEDs are illuminated when OMNI is selected Momentary contact push button switches below each LED select a single direction providing instant switching of directions without rota...

Page 3: ...ast selected direction While in the OMNI mode a new direction may be selected immediately by pushing its corresponding switch The omnidirectional option in the DXE CC 4SQR Control Console is only func...

Page 4: ...ower ON Wait until the first and last LEDs stop blinking 2 Press any two of the pushbutton switches simultaneously and hold them in LEDs will start to blink until the blinking stops The factory defaul...

Page 5: ...ur Square Control Console or you can use the custom label that is included The number one default position on the Transmit Four Square Controller is the first red push button on the left Depending on...

Page 6: ...or relay line input The keying signal has essentially no delay on pass through If you switch antenna positions while transmitting the controller waits until you stop transmitting before switching ante...

Page 7: ...Ground For other systems that usually require a 3 conductor cable we suggest the use of COM CW4 Four Conductor Control Cable four conductor control cable recommended to allow for future upgrade to DX...

Page 8: ...g instructions for return to DX Engineering transportation charges prepaid by Buyer Every such claim for breach of these warranties shall be deemed to be waived by Buyer unless made in writing The abo...