87
/
98
SM-1 Ev4/100901
ILD02
Op.
Description
Tools
Picture
1
Release and open the lateral cover - Accumulator
2
Disconnect the Accumulator
Wrench Flat 10
3
Mount the Beacon by help of Lamb bracket to the
Stabilizer. Stabilizer is placed left from the
accumulator.
Place the Cable in between the Sliding bar and
stabilizer.
Between the Beacon bracket and lateral cover must
be the distance.
Between the Beacon and top Cover of the machine
must be distance.
Wrench Imbus 4
4
Disconnect Connector of the signaling panel.
5
By help the small screwdriver dismount the blue
and red cable from the connector cover.
Screwdriver flat 2
mm
6
Cut the original pin faston 6,3
Pincers
7
Connect red cable of the main harness with red
cable of the beacon cable and blue cable of the
main harness with blue cable of the beacon cable.
Connect cables by help of connector faston - female
and mount the pin back to the connector cover. (see
the cables orientation)
x
x
Connector pliers