TPR 40, 15 kW - 15
Part No 9045
Safety Considerations
Read all instructions before the machine/installation is
commissioning.
Th
e equipment must be installed and maintained properly
by qualifi ed personnel who have study this user instruction.
Dustcontrol does not take responsibility for defective instal-
lation or maintenance.
Warning!
When using electric machines, basic safety
precautions should always be followed to reduce the risk
of fi re, electric shock and personal injury, including the
following:
1. Work area environment
Keep the area around the central unit clean. Do not
store or work with fl ammable liquids or gases near
the machine.
2. Overload
If there is an alarm signal it should be carefully
checked out to see that the machine is un damaged. If
there are any damaged parts these should be repaired
by a Dustcontrol authorized service centre. Always
follow the regulations pertinent to the material you
are working with. Do not use the machine for pur-
poses that it is not intended for.
3. Bodily
injuries
Warning - High negative pressure
Do not start the pump without having it connected
to the duct work. Do not adjust the vacuum relief
valve while the pump is operating. Never let the
suction come in contact with parts of the body, for
example a hand. Th
e pump generates a high negative
pressure, severe injury may result.
Warning - Very hot exhaust air
Exhaust air can be very hot, up to 150
O
C.
4. Electricity
A separate lockable disconnect must be installed
where it is readily accessible to the pump. Do not
repair the electric components yourself, get somebo-
dy qualifi ed. Faults may cause injury. Th
e electrical
connections may only be performed by a certifi ed
electrician. See also under section 7, ’Warning’.
5. Important
measure
Th
e electrical disconnect should be locked in the
”off ” position before demounting the safety panels or
ducting.
6. Checking for damage
Check the machine regularly for damage. If there
are any damaged parts these should be repaired by a
Dustcontrol authorized service centre.
7. Warning
Use only accessories and replaceable parts which are
available in Dustcontrol catalogue. When using non-
genuine parts, especially fi lters and plastic sacks, dust
leaks could occur which may be hazardous to health.
TECHNICAL DATA
,
TPR 40
description
Pump RPM
rpm
4000
Weight kg
400
Max dP
kPa
26*
Nominal pressure kPa
20
Max Q
m
3
/h 1200
Sound level of unit 1 m dB(A)
66
Inlet/Outlet Ømm
160/160
* Standard DC Green System, Max 22 kPa
Technical Data
PART NO/MOTOR Hz
TPR 40
230 V
50
106802/15 kW
400 V
50
106800/15 kW
460 V USA/CAN
60
106805/20 HP
575 V CAN
60
106806/20 HP
POWER RATING
EN
G
L
ISH