DC 5800TR - 10
Part No 9458-B
Operation
Connect the machine to compressed air.
Th
e fi lter should be cleaned 1-2 times per day with conti-
nuous running.
Reverse pulse fi lter cleaning:
1. Start the machine.
2. Close the shutter valve on the machines inlet.
3. With slow, even motion open the pulse top by lifting
the handle. Repeat three to six times.
4. Open the shutter valve.
Th
e plastic sack should be changed only after the fi lter has
been cleaned. Th
e sack should be changed when the dust level
is about 5 cm under the foot valve. Th
e plastic sack should
be sealed after removal from the machine.
Use only original plastic sacks.
Note! Low main pressure and damages in the compres-
sed-air line will result in poor performance.
Service
With cleaning and maintenance on the machine, the unit
should be turned off .
Th
e fi ne fi lte should be changed at least once per year. Use
only original spare parts. If the machine is used with a
microfi lter/HEPA fi lter, this should be changed every 300
running hours, Use breathing protection when changing
the fi lter. Used fi lters should be sealed in a plastic sack and
disposed of properly.
Th
e DC 5800TR should be performance tested at least once
per year because it may be used with hazardous materials.
Worn parts must be replaced.
Never compromise the function of the DC 5800 TR, use
only original spare parts.
Th
e warranty period for this machine is two years and co-
vers manufacturers faults. Th
e warranty is valid under the
condition that the machine is used under normal conditions
on the task for which it was designed and is maintained
properly. Normal wear is not covered by this warranty.
Warranty
Service performed by other than Dustcontrol or its aut-
horized agent voids automatically the warranty. No other
warranty express or implied is applicable.
Other accessories — see Dustcontrol catalogue
.
Accessories
Description
Part
no
Plastic sack, Smartopac
46145
Plastic sack, asbestos
4690
Fine fi lter
429204
Microfi lter
42869