DC 1800 - 14
Part No 94114-B
2011-05-11
Problem
Fault
Solution
Motor will not start.
Machine not connected.
Make sure connection.
The motor stops directly
Incorrect fuse.
Change to correct circuit.
after starting.
Fan runs but no suction.
Hose not connected.
Connect the hose.
Hose plugged.
Find and remove block.
Fan runs but poor suction.
Hole in the hose.
Change or repair hose.
Plugged
fi lter.
Clean or change fi lter.
Hose too long or too small.
Change the hose.
Hose is kinked.
Check and free.
Machine top is mounted
Adjust the mounting.
incorrectly.
Dust is packed in the
Take off the top and clean
cyclone.
out.
Machine blows dust.
Filter is perforated or has
Check the fi lters and change
come loose.
if necessary.
Abnormal sound from
Order service.
machine.
TROUBLE SHOOTING
Warranty
Th
e warranty period for this machine is two years and co-
vers manufacturers faults. Th
e warranty is valid under the
condition that the machine is used under normal conditions
on the task for which it was designed and is maintained
properly.
Normal wear is not covered by this warranty. Service per-
formed by other than Dustcontrol or its autho-rized agent
voids automatically the warranty. No other warranty express
or implied is applicable.
Description Part
No
Collection sack, standard
42291
Fine fi lter, cellulosa with
integrated fi lter cover
42029
Fine fi lter, polyester with
integrated fi lter cover
42028
Other accessories, see Dustcontrol catalogue.
Accessories
Microfi lter
42027
Basket for plastic bag
42369
Description Part
No