6
5. Handling And Installation
Important
During all lifting operations, make sure the packaged machine is firmly anchored to avoid
it tipping up or being accidentally dropped. Always load/unload trucks in adequately
lit areas.
5.1. Lifting and transporting the packaged machine
The machine, packaged on a wooden pallet by the Manufacturer, must be loaded using suitable equipment
onto the transporting vehicle. At destination, it must be unloaded using similar means.
A fork lift truck must always be used to lift the packaged body of the machine. Handle with care to avoid
knocking or overturning the machine.
5.2. Checks on delivery
When the carrier delivers the machine, make sure the packaging and machine are both whole and undamaged.
If the machine is damaged, make sure the carrier is aware of the damage and before accepting the goods,
reserve the right (in writing) to request compensation for the damage.
5.3. Unpacking
Important
When unpacking the machine, the operator must be provided with the necessary personal
protection devices (gloves, goggles, etc) to limit the risk of accident.
Unpack the machine as follows:
•
Cut and remove the plastic straps;
•
Remove the cardboard;
•
Remove the bags in the battery compartment (in the detergent tank) and check the contents:
•
product literature;
•
battery bridges with terminals;
•
1 battery charger connector ;
•
Depending on the model, remove the metal brackets or cut the plastic straps fixing the machine
chassis to the pallet;
•
Using a sloping ramp, push the machine backwards off the pallet;
•
Unpack the brushes and squeegee
•
Clean the outside of the machine in respect of safety regulations;
•
After unpacking the machine, install the batteries. See relevant sections in this manual.
•
The packaging may be kept as it can be reused to protect the machine if it is moved to another site
or to a repair workshop. Otherwise it must be disposed off in compliance with local legislation.
5.4. Power supply batteries
Two different types of battery may be installed on these machines: Deep Cycle and AGM
5.4.1. Batteries: preparation
The machines are set up at the factory based on the battery package selected. The default
setting on the machines is for Deep Cycle (Lead-Acid) batteries.
Information
The batteries are normally supplied filled with acid and ready for use. If the batteries are dry, before mounting
them on the machine, proceed as follows:
Summary of Contents for Hurricane 400 Eco