OVERFILLING PROPANE TANKS IS HAZARDOUS
.
The tank should
NEVER
be completely filled with liquid propane.
80% of the total tank volume is to be considered at
ALL
times as full. EXPANSION MUST BE ALLOWED FOR. Propane
Buffer tanks are equipped with a fixed liquid level gauge which contacts the liquid level at 80% of container capacity,
allowing 20% for expansion. The top part of this device must be unscrewed counterclockwis
e so that vapor can escape
through the small hole it its side, as the tank is refilled. When the escaping vapor starts to give way to liquid, the device
must be quickly closed and the propane nozzle turned off.
‘”IMPORTANT””
The engine and the fuel system on your floor care machine are designed to run on fuel vapor, not fuel
liquid. Overfilling the propane tank will result in damaging the lock off and/or regulator. This will
VOID
the
WARRANTY
on
these components.
13