When routeing the cables, maintain the
correct gaps between control cables and
supply cables.
❯
Guide the cables of the compressor units
through the strain relief and fasten.
❯
Plug the connector of the temperature sensor
and power supply of the compressor unit into
the sockets provided.
Connect the network cable for the monitoring
software
A network connection is only required
when using monitoring software.
❯
Connect the network cable to the network
socket.
Installation of the cover
❯
Connect the operating panel cable again.
❯
Attach the cover of the control again and fas-
ten it with the screw.
DANGER
Risk of electric shock due to defective
mains cable
❯
Mains cables must not be allowed to
come into contact with any hot surfa-
ces on the unit.
❯
Attach the cables using the cable clips.
8.3
Establishing the compressed
air connection
The supplied flexible pressure hose
between the pipe system and the com-
pressor prevents vibrations from being
transmitted and thus reduces noise. This
ensures safe and reliable operation.
❯
Connect the premounted connecting sleeve on
the pressure hose to the quick release coupling
of the distributor block.
❯
Measure the required length of pressure hose
and shorten the pressure hose if necessary.
❯
Slide the second hose nozzle in place and
secure with a hose clip.
❯
Connect the connecting sleeve on the pressure
hose to the piping system.
8.4
Pressure reducer
❯
Insert the pressure reducer into the quick
release coupling.
❯
Insert the pressure hose into the quick release
coupling on the pressure reducer.
Assembly
20