Assembling the remaining thread monitor (1-needle machines)
10
Additional Instructions M-TYPE DELTA - 00.0 - 08/2019
Fig. 4: Assembling solenoid valve and RFW PCB (3)
10. Tilt the machine head.
11. Remove the dummy plate from the valve block (13).
Information
The valve block and the corresponding connectors and hoses are
included in the pneumatic small parts pack (part number: 0867 594304).
12. Screw the solenoid valve (3) in at the available space on the valve
block (13).
13. If not yet present, tighten valve block (13) and bracket (14) using
the screws (15).
14. Connect the hose (16) to the compressed air maintenance unit.
Make sure to lay the hose (16) such that it will not be pinched when
the machine head is erected.
15. Tighten the holder (9) to the base plate using the screws (17).
(3) - Solenoid valve
(9) - Holder
(10) - Cable RFW sensor
(11) - Cable
(12) - Cable
(13) - Valve block
(14) - Bracket
(15) - Screws
(16) - Hose
(17) - Screws
③
⑬
⑭
⑨
⑰
⑪
⑩
⑫
⑮
⑯