Connecting the throat plate slide interrogator
14
Additional Instructions 867 M-TYPE - 00.0 - 05/2018
Fig. 15: Connecting the throat plate slide interrogator (5)
8. Connect the cable of the throat plate slide interrogator at any available
slot
X2
/
X3
/
X4
/
X5
(11).
9. Connect the corresponding slot on the machine distributor (depending
on the machine) to plug connection
X6
(12).
10. When the circuit board (8) is connected to the machine, connect plug
connection
X13
(9) with plug connection
X1
(14).
11. Set all DIP switches (13) whose slots
X1
-
X5
are NOT occupied to
position
ON
.
Information
The
ON
position of the DIP switches signifies that no interrogator is
connected at the corresponding slot or that the function of the respective
interrogator is switched off.
The DIP switches (13) shown in the figure below MUST be set to the
following position:
• DIP switch
1
:
ON
• DIP switch
2
:
OFF
• DIP switch
3
:
OFF
• DIP switch
4
:
ON
• DIP switch
5
:
ON
The needle cover interrogator has been successfully assembled and
connected.
Proceed by testing the functionality of the throat plate slide interrogator
(
(11) - Plug connection
X2
-
X5
(12) - Plug connection
X6
(IN)
(13) - DIP switch 1-5
(14) - Plug connection
X1