Operating manual part II
© 2010 Dürkopp Adler AG
II-9
L
C
P
Min
Max
Preset Unity
Description
Seam ways
t
07 00 0
2
0
-
Treatment position-2 in seam ways.
0 = Demolition of the seam. The next seam way is sewn; The
seam is broken off with thread trimmer at the last seam of
the program.
1 = Demolition of the seam with thread performances (even if
inactive). The next seam process is a free seam.
2 = Demolition of the seam with thread performances (even if
inactive). Seam program is stopped.
t
07 01 0
1
0
-
Automatic system business.
0 = off;
1 = on
Motor
t
08 00 500
9999
3400
rpm
Maximum speed
t
08 01 100
400
150
rpm
Minimal speed
t
08 02 100
1000
150
rpm
Positioning speed
t
08 03 1
100
20
rpm/ms
Acceleration ramp
t
08 04 1
100
30
rpm/ms
Braking ramp
t
08 05 0
1
1
-
Direction of rotation of the motor
0 = on the left;
1 = on the right
t
08 06 0
2
1
-
Motor brake at the normal stop
0 = Brakes for the duration of t0805;
1 = Brake durably actively at the stop
2 = Position will be hold permanently
t
08 07 0,1
6,0
3,0
A
Holding current at the machine stop
t
08 08 0
255
80
-
Reaction rate at changes of the needle position
t
08 09 0
999
200
ms
Period of the motor brake
t
08 10 -
-
-
-
Setting the reference position
t
08 11 -
-
-
-
Setting the needle positions
t
08 12 0
359
16
°
Lower needle position (Position 1)
t
08 13 0
359
326
°
Thread lever up position (Posit ion 2)
t
08 14 0
359
350
°
Direction finder position
t
08 15 0
359
245
°
on threading position
t
08 20 -
-
-
-
Calibrating pedal
t
08 21 12
64
24
Steps
Number of speed steps of the pedal
t
08 22 0
4
3
-
Speed curve
t
08 23 10
255
90
ms
Debouncing of the position-1
t
08 24 5
255
15
ms
Debouncing of the position-2
t
08 30 0
1
0
-
Shows the machine speed
0 = No;
1 = Yes
t
08 31 0
1
0
-
Shows the current needle position
0 = No;
1 = Yes
t
08 32 -
-
-
-
The Needle will move to the upper needle position if the
energy is on and the pedal was used.
0 = No;
1 = Yes
t
08 40 500
9999
3000
rpm
Speed limitation DB3000