1.1.3  Developer-level 

Min 

Max 

Preset  Unity 

Description 

Bartack 

00  01  0 

359 

15 

° 

Mechanical switching angle of th e bartack 

Thread trimmer 

02  00  0 

360 

100 

The FA speed shall angle be reached before switching on 
the magnets. 

Seam ways 

07  00  150 

9999 

1500 

rpm 

Speed limitation for seam ways 

07  01  1 

20 

Stitches 

Stitches for the speed limitation by seam ways 

Motor 

08  00  1 

9999 

3800 

rpm 

Maximum motor speed 

08  01  1 

100 

40 

rpm/ms 

Maximum acceleration or deceleration 

08  02  0 

50 

20 

Kgcm² 

Mechanical inertia 

08  10  0,1 

100,0 

2,2 

Ohm 

Stator resistance 

08  11  1 

200 

mH 

Stator inductance 

08  12  0,1 

100,0 

49,0 

V/1000rpm  EMK 

08  13  0,1 

20,00 

11,00 

Maximum stator current 

08  14  1 

10 

Pole couple number 

08  20  0 

255 

44 

Factor K

pn

 of the speed control 

08  21  0 

255 

30 

Factor K

in

 of the speed control 

08  22  0 

255 

Factor K

dn

 of the speed control 

08  23  0 

255 

24 

Pre control of the speed control in the breaking sequence 

08  30  0 

255 

Factor K

ps

 of the distance control 

08  31  0 

255 

Factor K

is

 of the distance control 

08  32  0 

255 

Factor K

ds

 of the distance control 

08  40  0 

255 

76 

Factor K

px

 of the position control 

08  41  0 

255 

64 

Factor K

dx

 of the position control 

08  42  0 

255 

16 

Inc 

Increments for the add-on connection of the PD situation 
control system 

08  43  0 

1000 

2,857° 

Angle to the positioning 

08  44  0 

1000 

16 

Inc 

Increments for the position speed 

08  50  0 

Choice of the pedal 
0 =  Analogous; 
1 =  Digital 

08  51  0 

endurance test active 
0 =  No; 
1 =  Yes 

08  52  0,1 

99,99 

5,00 

Period motor on

 

08  53  0,1 

99,99 

5,00 

Period motor off 

08  54  1 

9999 

900 

Period oft the endurance test 

08  55  0 

2000 

180 

rpm 

Speed for the reference drive 

Thread tension 

09  01  5 

100 

50 

Pulse duty ratio at the on threading help 

Machine run blockage 

50  00  0 

Machine run blockage 
0 =  off; 
1 =  on 

50  01  0 

The mode of operation from machine run blockage switch 
0 =  NC; 
1 =  NO 

Summary of Contents for DAC BASIC - CLASS 271 PART II V 12-2010

Page 1: ...part II class 867 0791 867901 D rkopp Adler AG PO Box 17 03 51 D 33703 Bielefeld Potsdamerstr 190 D 33719 Bielefeld Phone 49 0 521 9 25 00 Fax 49 0 521 9 25 24 35 www duerkopp adler com Ausgabe Editio...

Page 2: ...ks of the respective owners The publisher and the author make no claim to these trademarks While every precaution has been taken in the preparation of this document the publisher and the author assume...

Page 3: ...ual part II 2010 D rkopp Adler AG II 3 Contents PART II 4 1 Parameter 4 1 1 Parameter of class 867 4 1 1 1 Operator level 4 1 1 2 Technician level 5 1 1 3 Developer level 17 1 2 Sets of parameters for...

Page 4: ...x Preset Unity Description Bobbin thread counter and bobbin thread monitor o 06 00 0 4 0 Activate the bobbin thread counter 0 off 1 Bobbin thread counter A 2 Bobbin thread counter B 3 Bobbin thread co...

Page 5: ...additional route A 0 off 1 on t 00 06 0 500 0 ms Delay time up to the speed release after the start backtack t 00 10 300 2500 1000 rpm End backtack speed t 00 11 0 254 9 10 Pre control angle when swi...

Page 6: ...Simple end backtack 1 Double end backtack 2 End multiple backtack t 00 45 0 1 0 Switching on the manual backtack 0 Needle below 1 Needle above t 00 46 0 1 0 Turning the manual backtack off 0 Needle b...

Page 7: ...11 out switching angle FL t0112 t 01 01 0 359 30 on switching angle of the thread clamp t 01 02 0 359 200 off switching angle of the thre ad clamp t 01 11 0 359 50 on switching angle of the sewing foo...

Page 8: ...of the machine after switching the sewing foot lifting off t 03 11 0 255 40 ms Turn on delay of the sewing foot lifting at speed 0 t 03 12 0 255 200 ms Turn on delay of the sewing foot lifting at the...

Page 9: ...e normal stop 0 Brakes for the duration of t0805 1 Brake durably actively at the stop 2 Position will be hold permanently t 08 07 0 1 6 0 3 0 A Holding current at the machine stop t 08 08 0 255 80 Rea...

Page 10: ...tension magnet at the trimming process t 09 21 0 255 50 ms Delay time for turning the tension magnet off at the trimming process t 09 50 0 999 100 ms Drive time of the thread tension magnet in the tim...

Page 11: ...ric end stop t 11 31 0 1 0 Output of function module 2 X2 20 inverted 0 No 1 Yes t 11 32 0 1 0 Deactivation of function module 2 after trimming process 0 No 1 Yes t 11 60 0 6 0 Function of module 3 X2...

Page 12: ...ck 3 Lifting with bartack and sewing foot t 14 01 0 1 0 Lifting roller when enabling high lift for walking foot 0 No 1 Yes t 14 02 0 1 0 Stitch counting after sewing foot lifting till roller remains l...

Page 13: ...l X2 1 High lift for walking foot not stored X2 2 High lift for walking foot stored X2 3 No Function X2 4 No Function X2 6 No Function X2 7 No Function 3 Outputs X1 15 Output function module 3 module...

Page 14: ...t machine connector Pin 14 0 no function 1 on threading help 2 Bartack suppression recall 3 Manual bartack 4 Half stitch 5 Full stitch 6 Direction finder position 7 Turning back 8 Input function modul...

Page 15: ...help 2 Bartack suppression recall 3 Manual bartack 4 Half stitch 5 Full stitch 6 Direction finder position 7 Turning back 8 Input function module 1 9 Input function module 2 10 Input function module 3...

Page 16: ...g back 8 Input function module 1 9 Input function module 2 10 Input function module 3 11 Switch high lift for walking foot 12 Ornamental Backtack 13 Needle cooling t 52 40 0 1 0 Key lock for the initi...

Page 17: ...2 0 255 0 Factor Kdn of the speed control d 08 23 0 255 24 Pre control of the speed control in the breaking sequence d 08 30 0 255 6 Factor Kps of the distance control d 08 31 0 255 3 Factor Kis of th...

Page 18: ...positioning Miscellaneous of the control d 51 00 1 255 40 ms Period for raising off Umag on 33V d 51 01 1 255 5 ms Period for the DeEnergizer process d 51 02 0 1 16 00 16 00 kHz Adjust the PWM freque...

Page 19: ...Sets of parameters for class 867 Parametersatz 867 190x22 M 867 190x42 M 867 290x22 M 867 290x42 M F r Unterklassen 867 190122 M 867 190142 M 867 290122 M 867 290142 M L C P Preset Preset Preset Prese...