Min 

Max 

Preset  Unity 

Description 

02  01  0 

Pedal position for starting the cutting process. 
0 =  Position -2; 
1 =  Position -1 

02  10  0 

359 

25 

° 

on switching angle t 08 12 <= t  02 10 < t 02 11  

02  11  0 

359 

265 

° 

off switching angle t 02 10 < t  02 11 <= t 08 13 

02  20  0 

255 

ms 

Delay time for a repeated activation of the Cutting magnet. 

02  21  0 

255 

ms 

Delay time for turning the cutting magnet off 

Sewing foot lifting 

03  00  0 

sewing foot lifting active 
0 =  No;  
1 =  Yes 

03  10  0 

255 

80 

ms 

Intermediate lag of the machine after switching the sewing 
foot lifting off 

03  11  0 

255 

40 

ms 

Turn-on delay of the sewing foot lifting at speed 0 

03  12  0 

255 

200 

ms 

Turn-on delay of the sewing foot lifting at the seam end 

03  50  0 

999 

200 

ms 

Drive time of the sewing foot lifting magnet in the time 
period t

03  51  5 

100 

100 

Pulse duty ratio in the time period t

1

 

03  52  0,0 

600,0 

0,0 

Drive time of the foot lifting magnet in the time period t

2

  

(If you adjust 0s the thread clamp magnet will be driven 
permanently)  

03  53  5 

100 

40 

Pulse duty ratio in the time period  t

03  54  0 

Increasing U

mag

 when the foot lifting magnet will be driven 

0 =  No;  
1 =  Yes 

Soft start 

05  00  120 

1000 

400 

rpm 

Soft start speed 

05  01  1 

99 

Stitches 

Number of soft start stitches 

Summary of Contents for DAC BASIC - CLASS 271 PART II V 12-2010

Page 1: ...part II class 867 0791 867901 D rkopp Adler AG PO Box 17 03 51 D 33703 Bielefeld Potsdamerstr 190 D 33719 Bielefeld Phone 49 0 521 9 25 00 Fax 49 0 521 9 25 24 35 www duerkopp adler com Ausgabe Editio...

Page 2: ...ks of the respective owners The publisher and the author make no claim to these trademarks While every precaution has been taken in the preparation of this document the publisher and the author assume...

Page 3: ...ual part II 2010 D rkopp Adler AG II 3 Contents PART II 4 1 Parameter 4 1 1 Parameter of class 867 4 1 1 1 Operator level 4 1 1 2 Technician level 5 1 1 3 Developer level 17 1 2 Sets of parameters for...

Page 4: ...x Preset Unity Description Bobbin thread counter and bobbin thread monitor o 06 00 0 4 0 Activate the bobbin thread counter 0 off 1 Bobbin thread counter A 2 Bobbin thread counter B 3 Bobbin thread co...

Page 5: ...additional route A 0 off 1 on t 00 06 0 500 0 ms Delay time up to the speed release after the start backtack t 00 10 300 2500 1000 rpm End backtack speed t 00 11 0 254 9 10 Pre control angle when swi...

Page 6: ...Simple end backtack 1 Double end backtack 2 End multiple backtack t 00 45 0 1 0 Switching on the manual backtack 0 Needle below 1 Needle above t 00 46 0 1 0 Turning the manual backtack off 0 Needle b...

Page 7: ...11 out switching angle FL t0112 t 01 01 0 359 30 on switching angle of the thread clamp t 01 02 0 359 200 off switching angle of the thre ad clamp t 01 11 0 359 50 on switching angle of the sewing foo...

Page 8: ...of the machine after switching the sewing foot lifting off t 03 11 0 255 40 ms Turn on delay of the sewing foot lifting at speed 0 t 03 12 0 255 200 ms Turn on delay of the sewing foot lifting at the...

Page 9: ...e normal stop 0 Brakes for the duration of t0805 1 Brake durably actively at the stop 2 Position will be hold permanently t 08 07 0 1 6 0 3 0 A Holding current at the machine stop t 08 08 0 255 80 Rea...

Page 10: ...tension magnet at the trimming process t 09 21 0 255 50 ms Delay time for turning the tension magnet off at the trimming process t 09 50 0 999 100 ms Drive time of the thread tension magnet in the tim...

Page 11: ...ric end stop t 11 31 0 1 0 Output of function module 2 X2 20 inverted 0 No 1 Yes t 11 32 0 1 0 Deactivation of function module 2 after trimming process 0 No 1 Yes t 11 60 0 6 0 Function of module 3 X2...

Page 12: ...ck 3 Lifting with bartack and sewing foot t 14 01 0 1 0 Lifting roller when enabling high lift for walking foot 0 No 1 Yes t 14 02 0 1 0 Stitch counting after sewing foot lifting till roller remains l...

Page 13: ...l X2 1 High lift for walking foot not stored X2 2 High lift for walking foot stored X2 3 No Function X2 4 No Function X2 6 No Function X2 7 No Function 3 Outputs X1 15 Output function module 3 module...

Page 14: ...t machine connector Pin 14 0 no function 1 on threading help 2 Bartack suppression recall 3 Manual bartack 4 Half stitch 5 Full stitch 6 Direction finder position 7 Turning back 8 Input function modul...

Page 15: ...help 2 Bartack suppression recall 3 Manual bartack 4 Half stitch 5 Full stitch 6 Direction finder position 7 Turning back 8 Input function module 1 9 Input function module 2 10 Input function module 3...

Page 16: ...g back 8 Input function module 1 9 Input function module 2 10 Input function module 3 11 Switch high lift for walking foot 12 Ornamental Backtack 13 Needle cooling t 52 40 0 1 0 Key lock for the initi...

Page 17: ...2 0 255 0 Factor Kdn of the speed control d 08 23 0 255 24 Pre control of the speed control in the breaking sequence d 08 30 0 255 6 Factor Kps of the distance control d 08 31 0 255 3 Factor Kis of th...

Page 18: ...positioning Miscellaneous of the control d 51 00 1 255 40 ms Period for raising off Umag on 33V d 51 01 1 255 5 ms Period for the DeEnergizer process d 51 02 0 1 16 00 16 00 kHz Adjust the PWM freque...

Page 19: ...Sets of parameters for class 867 Parametersatz 867 190x22 M 867 190x42 M 867 290x22 M 867 290x42 M F r Unterklassen 867 190122 M 867 190142 M 867 290122 M 867 290142 M L C P Preset Preset Preset Prese...

Reviews: