About the mounting instructions

These mounting instructions come as part of the Duravit 

product and should be read carefully prior to installation.

Target readership and qualifications

The product and associated water connection should only be 

installed by qualified plumbers. The electrical installation 

should only be carried out by qualified electricians.

Explanation of the signal words and symbols

 

DANGER

Indicates a hazardous situation which, 

if not avoided, will result in death or 

serious injury.

 

WARNING

Indicates a hazardous situation which, 

if not avoided, could result in death or 

serious injury.

 

CAUTION

Indicates a hazardous situation which, 

if not avoided, could result in minor 

or moderate injury.

NOTICE

Is used to address practices not 

related to physical injury.

Link to the 

Electrical Installation 

section

Link to the 

installation information

 in this section

Link to other 

instructions

Link to the 

Water Installation

 section

Inspection (e.g. for scratches)

Do not kink hose

Check for leaks and leak-tightness

Risk of fatal electric shock!

 

> The product has to be correctly earthed. Do NOT operate the 

product without proper grounding.

 

> Do NOT remove individual components.

 

> Connect the product only to the specified power supply.

 

> NEVER touch the power supply cable with wet hands.

 

> When working on electric components, disconnect the power 

supply.

 

> If the supply cord is damaged, it must be replaced by the 

manufacturer, its service agent or similarly qualified persons 

in order to avoid a hazard.

 

> Check rated power and choose cable cross section 

accordingly.

Product and/or property damage

 

> Do NOT install the product in a room exposed to excessive 

moisture. Ensure sufficient ventilation to avoid condensation 

in electric components.

 

> Only use the parts in the installation kit to avoid 

malfunctions.

 

> Do NOT use attachments not recommended by Duravit.

Freezing water

If the room temperature is too low, this can cause damage to 

the product.

 

> Do NOT install the product in rooms where there is a danger 

of frost. The room temperature must not be less than  

4 °C (39 °F).

Condensation

Condensation may occur when moving from a cold location to a 

warm location and can cause damage to the product.

 

> Leave the unit switched off for a few hours if it has been 

moved from a cold location to a warm location.

Standards and regulations

The breach of local and country-specific regulations and 

standards can cause damage to the product and/or property 

damage.

 

> Local installation regulations, country-specific standards 

and the Low Voltage Directives shall be observed at all times.

8

 57313_Mounting_SeWa_Starckf_EU/20.01.2

Summary of Contents for SensoWash Starck f

Page 1: ...SensoWash Starck f 650000 01 2 00 4320 650001 01 2 00 4310 ...

Page 2: ...ct only to the specified power supply NEVER touch the power supply cable with wet hands When working on electric components disconnect the power supply If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Check rated power and choose cable cross section accordingly Product and or property damage Do NOT ins...

Page 3: ...nstallation kit see www pro duravit com 4 Installing the noise reduction gasket If the noise reduction gasket is included in the delivery the z thickness must also be taken into consideration z 50 mm Install the noise reduction gasket 20 Choosing and installing mounting clip The delivery contains two mounting clips Choose clip according to cable diameter 25 26 Installing interface with actuator pl...

Page 4: ...st 800 mm 31 of feed cable exposed Install circuit breaker The product itself does not have electrical leakage protection function it must be installed in circuit where there is leakage protection device installed Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules and having a contact separation in all poles that provide full disconnection under ov...

Page 5: ...nce of the product Check the water quality in your region Duravit recommends the installation of a water softener with water hardness 14 dH 2 5 mmol l Make sure to descale the product regularly The app will send an automatic reminder Adjust the descaling settings according to the water hardness in your region App Menu Care Descaling Only use descaling agents provided or approved by Duravit Water h...

Page 6: ...100 57313_Mounting_SeWa_Starckf_EU 20 01 2 650001 01 2 00 4310 650000 01 2 00 4320 ...

Page 7: ... 800 mm M 12 WA IG 180 M 12 z 50 m m 35 mm 1 2 57313_Mounting_SeWa_Starckf_EU 20 01 2 101 12 11 10 9 8 7 6 5 4 3 2 1 ...

Page 8: ...15 Nm 1 2 L N PE 102 57313_Mounting_SeWa_Starckf_EU 20 01 2 22 21 20 19 18 17 16 15 14 13 ...

Page 9: ...1 2 2x M4x16 1 2 1 2 1 2 1 2 1 2 WD5003 012 000 WD5003 012 000 57313_Mounting_SeWa_Starckf_EU 20 01 2 103 33 32 31 30 29 28 27 26 25 24 23 ...

Page 10: ... Ø 5 mm Ø 2x S5 2x ST8x30 1 2 1 2 1 2 48 mm 1 104 57313_Mounting_SeWa_Starckf_EU 20 01 2 43 42 41 40 39 38 37 36 35 34 35 36 48 58 41 44 37 44 45 47 52 58 ...

Page 11: ...1 2 43 mm 1 Ø 5 mm Ø 2x S5 2x ST4x20 57313_Mounting_SeWa_Starckf_EU 20 01 2 105 51 50 49 48 47 46 45 44 52 53 ...

Page 12: ...1 2 M2x8 106 57313_Mounting_SeWa_Starckf_EU 20 01 2 58 57 56 55 54 ...

Page 13: ......

Page 14: ...erve the right to make technical improvements and design modifications to the products illustrated DURAVIT AG P O Box 240 Werderstr 36 78132 Hornberg Germany Phone 49 78 33 70 0 Fax 49 78 33 70 289 info duravit com www duravit com ...

Reviews: