![DURAVIT SensoWash 212051 Mounting Instructions Download Page 8](http://html.mh-extra.com/html/duravit/sensowash-212051/sensowash-212051_mounting-instructions_2542090008.webp)
en
2.4 Hygiene
Damage to health caused by dirty or polluted water.
Operating the cleansing functions with dirty or polluted
water can cause health damage.
> Supply the product with cold drinking water from the
main water system.
> Do NOT connect any waste water, grey water,
industrial water, sea water or other untreated or
semi-treated water.
> The new hose-sets supplied with the appliance are to
be used and old hose-sets should not be reused.
> Activate additional self-cleaning via app if the product
has not been used for two weeks or above.
→ App: Menu – Care – Self-cleaning
2.5
Avoiding product damage
General precautions
> Only use the parts in the installation kit to avoid
malfunctions.
> Only use attachments recommended by Duravit.
Damage through freezing water
Do NOT install and operate the product in rooms where
there is a danger of frost. The room temperature must
not be less than 4 °C (39 °F).
Damage through limescale build-up
In regions with hard water, limescale can build-up.
Limescale can impair the performance of the product.
> Check the water quality in your region. Duravit
recommends the installation of a water softener with
water hardness ≥ 14 °dH (2.5 mmol/l).
3.
Requirements at the installation location
The pre-installation is carried out properly. The water
and power supply for the product are installed properly.
> Access the pre-installation data sheet at
qr.duravit.com or www.duravit.com
> Ensure that there is enough floor space to install the
toilet and that bathroom door will open and close
without obstruction.
> Ensure that the lid will open and close without
obstruction against window frames, shelves and other
bathroom furniture.
4.
Drawings and plans
Position of water and electrical installation
60 mm
60 mm
32
5 mm
IG ½"
2
⅜
"
2
⅜
"
12 ¾"
> Install the water connection and water outlet in the
specified areas.
> Install electrical connection in the specified areas.
5.
Technical Data
Electrical
Rated voltage
61X XXX XX 2 XX XXXX
220 – 240 V, 50 – 60 Hz
61X XXX XX 1 XX XXXX
100 – 120 V, 50 – 60 Hz
(US, Taiwan models)
Rated power
1080 W
Circuit breaker
I
N
= 16 A
RCD
I
N
= 30 mA
Protection degree
IP X4
Protection class
I
Cable specification
Cross section
1 – 2.5 mm2
(17 – 14 AWG)
Water
Cold water
DN 15 (½")
Water pressure
0.07 – 0.75 MPa
(10 – 109 psi)
Water hardness
max. 2.4 mmol/l
(240 ppm)
8
54040_MI_SensoWash_1pWC
Summary of Contents for SensoWash 212051
Page 2: ...2 54040_MI_SensoWash_1pWC ...
Page 34: ...L N PE 4x 4x20 1 3 2 34 54040_MI_SensoWash_1pWC 22 21 20 19 18 17 16 15 14 13 24 23 ...
Page 35: ...3x 2 1 54040_MI_SensoWash_1pWC 35 26 25 27 28 29 ...
Page 37: ...54040_MI_SensoWash_1pWC 37 1 2 1 2 3 click C 2 1 3 2 1 D ...
Page 38: ...38 54040_MI_SensoWash_1pWC ...
Page 39: ...54040_MI_SensoWash_1pWC 39 ...