44
Factory setting
Setting range
Hygiene flush
Deactivated
On/Off
Number of flushes
1
1 to 10
Interval time
72 h
24 h, 48 h, 72 h...up to 240 h
Starting time delay
0
0, 1, 2, 3, 4, 5 (in 4 h steps)
Table 3: Setting the hygiene flush
Manual triggering
The toilet flush can be triggered manually in case of an emergency, a battery failure of
a defect on the actuator plate.
Removing the actuator plate
> Remove the actuator plate with the
suction cups supplied.
1
2
Triggering a flush
> Turn the enclosed threaded rod (service
accessories kit) in the opening of the
plate.