5

In insulation test mode, it indicates the measure value overflow.

Unsafe voltage warning. Indicates greater than 20V.
Continuity test function is selected.
Auto power off function is selected.
Insulation test indicator.
Source voltage rating for insulation test.
Timer unit.
Measure unit.

Display the Max, Min and Average value.

 

 

 

DISPLAY MESSAGES

Indicator

Description

batt

Appears on primary display, indicating the battery is too low for 

reliable operation. Replace the battery.

bat

Appears on auxiliary display, indicating that the battery is too low to 

perform the insulation test.

P r E S

Preset value.

POFF

Auto power off function is disabled.

LIVE

In insulation mode, it indicates that the Meter has detected the 

voltage on the input terminals.

DISC

In insulation mode, it indicates that the Meter peforms the auto 

discharge function. Do not touch any input terminals in this mode.

SAVE

Store measuring data.

dEL n:

Delete the selected data.

dEL ALL

Delete all memorised data.

COMP Hi

The upper limited value.

COMP Lo

The lower limited value.

- - - - COMP The limited value is invalid.

Beep function disabled.

 

BUTTONS

Summary of Contents for D03131

Page 1: ...1 3 DIGITAL MULTIMETER MODEL D03131...

Page 2: ...ons 7 Automatic Power Off 7 Hold Function 7 Relative Measurement 7 Insulation Test Lock 7 Storing Test Data 8 Reading Test Data 8 Delete Data 9 Compare Function 9 Timer Function 9 Max Min Avg 9 DAR PI...

Page 3: ...own voltage Do not apply more than the rated voltage as marked on the Meter between the terminals or between any terminal and earth ground Use caution with voltages above 30V AC RMS 42V AC peak or 60...

Page 4: ...ay COMP Compare function is selected PASS When the measured value is between the upper limited and lower limited value REL Relative function is selected DAR In insulation test mode display the DAR val...

Page 5: ...ion Replace the battery bat Appears on auxiliary display indicating that the battery is too low to perform the insulation test P r E S Preset value POFF Auto power off function is disabled LIVE In ins...

Page 6: ...position 9 Activate the compare function 10 Select one test output voltage for insulation test 11 Activate the Insulation test ROTARY SWITCH Position Function OFF Turn off the Meter power V DC Voltage...

Page 7: ...relative base Press the REL button to enter relative measurement and the Meter will record the initial value when pressing the key Displayed value Actual value Initial value Press the REL button agai...

Page 8: ...he READ button to display the data in memory Press to change the code and read the data accordingly DELETE DATA In READ mode press ENTER and the meter will display dEL n Press ENTER again to delete th...

Page 9: ...ER The lock function will be invalid and the Meter will start the Insulation test when pressing the MEASURE button When the time is due the test is stopped In Timer mode the current voltage and time i...

Page 10: ...nuity test features a beep that sounds as long as the circuit is complete The beep sounds when a short 3 INSULATION TEST Warning When testing voltage output do not rotate the rotary switch to prevent...

Page 11: ...tion of test Insulation Maximum Capacitive Load Operable with up to 1 F load Storage Temperature 40 C to 60 C Operating Temperature 0 C to 40 C Storage Altitude 12000m Operating Altitude 2000m 1000V C...

Page 12: ...SAL FOR CONSUMERS OF ELECTRICAL ELECTRONIC EQUIPMENT When this product has reached the end of its life it must be treated as Waste Electrical Electronics Equipment WEEE Any WEEE marked products must n...

Reviews: