INTRODUCTION

Screen

Rotary switch

Front Panel

Display Screen

Analogue bar

Primary Screen

Secondary 

Screen

Indicator

Description

Low battery indicator. Replace the battery as soon as the indicator 

appears.

LOCK

Indicates a test lock will be applied next time you press the TEST button 

on the Meter.

HOLD

Prevents the Meter from updating the display.

COMP

Compare function is selected.

PASS

When the measured value is between the upper limited and lower 

limited value.

REL

Relative function is selected.

DAR

In insulation test mode, display the DAR value.

PI

In insulation test mode, display the PI value.

TIMER

Timer function is selected.

MEMO

Store function is selected.

READ

View memory data. When the data is invalid the display will read ---

DC

DC voltage function is selected.

AC

AC voltage function is selected.

VDC

In insulation test mode, test voltage unit.

When the measurement value is lower than 0.

 

Summary of Contents for D03131

Page 1: ...1 3 DIGITAL MULTIMETER MODEL D03131...

Page 2: ...ons 7 Automatic Power Off 7 Hold Function 7 Relative Measurement 7 Insulation Test Lock 7 Storing Test Data 8 Reading Test Data 8 Delete Data 9 Compare Function 9 Timer Function 9 Max Min Avg 9 DAR PI...

Page 3: ...own voltage Do not apply more than the rated voltage as marked on the Meter between the terminals or between any terminal and earth ground Use caution with voltages above 30V AC RMS 42V AC peak or 60...

Page 4: ...ay COMP Compare function is selected PASS When the measured value is between the upper limited and lower limited value REL Relative function is selected DAR In insulation test mode display the DAR val...

Page 5: ...ion Replace the battery bat Appears on auxiliary display indicating that the battery is too low to perform the insulation test P r E S Preset value POFF Auto power off function is disabled LIVE In ins...

Page 6: ...position 9 Activate the compare function 10 Select one test output voltage for insulation test 11 Activate the Insulation test ROTARY SWITCH Position Function OFF Turn off the Meter power V DC Voltage...

Page 7: ...relative base Press the REL button to enter relative measurement and the Meter will record the initial value when pressing the key Displayed value Actual value Initial value Press the REL button agai...

Page 8: ...he READ button to display the data in memory Press to change the code and read the data accordingly DELETE DATA In READ mode press ENTER and the meter will display dEL n Press ENTER again to delete th...

Page 9: ...ER The lock function will be invalid and the Meter will start the Insulation test when pressing the MEASURE button When the time is due the test is stopped In Timer mode the current voltage and time i...

Page 10: ...nuity test features a beep that sounds as long as the circuit is complete The beep sounds when a short 3 INSULATION TEST Warning When testing voltage output do not rotate the rotary switch to prevent...

Page 11: ...tion of test Insulation Maximum Capacitive Load Operable with up to 1 F load Storage Temperature 40 C to 60 C Operating Temperature 0 C to 40 C Storage Altitude 12000m Operating Altitude 2000m 1000V C...

Page 12: ...SAL FOR CONSUMERS OF ELECTRICAL ELECTRONIC EQUIPMENT When this product has reached the end of its life it must be treated as Waste Electrical Electronics Equipment WEEE Any WEEE marked products must n...

Reviews: