Duratech megavoice 2000 Installation Manual Download Page 5

1.GENERAL
1.1 MEGAVOICE 2000

Congratulations ! You have selected a new intelligent Megavoice 2000 Voice announcer. 
The device can be used for many purposes with different sotware versions. The 
hardware is also expandable.

Megavoice is reliable. The voice recordings and set ups are stored into chip memory for 
more than 10 years without electricity.The device is supervised by watch dog, which 
resets the system if voltage is not good or the system is not operating normally. The 
case is made of durable aluminium. The interfaces are protected far better than the 
standards require.

Megavoice is easy to install. The case can be placed in any direction and can even 
stand on its side. There is a fixing metal under the unit for wall mounting. The case is 
designed to fit into many standard mechanics. Line cords can be terminad to RJ modular 
connector or to LSA+-frame. The units can be stacked up. Customer messages and set 
ups can be programmed before installation, because the unit do not need electricity for 
storing memory. The unit is also fully remote programmable.The unit is remote 
programmable with DTMF code. Standard telephone or cellular one can be used. 
Programming is as easy as 1-2-3 and many features are programmed with suitable 
default values.

 The lines acts as telephones with flash transfer. The 

lines can in/output signal without Dc-current to 600 ohm line also. There is also option 
for E&M lines. Basic system has line interfaces for headset and CD-player or recorder. 
The line level is adjustable from the front panel.The front panel dip switches are used for 
special cases and are not needed normally.  Front panel has also connector for separate 
or internal 32 character LCD display. It helps to program, study and read the system 
programming. It also indicates the incoming calls counter and displays free and used 
memory. Front panel has three leds; green, yellow, red like traffic lights. Normal green 
lights and everything is OK. Yellow indicated wait and red error. These leds indicated 
also the recording level: green OK, yellow OK, red too high. 

Basic unit can be expanded with expansion port. It can use for example 4 extra lines. 
Also there are many options: V.24 port for maintenance, real time clock, IO-port, cellular 
phone interface, relay outputs. Custom made interfaces are available on request.

.

Megavoice basic unit can store up 128s messages and the capacity can be extended to 
256 s or more.  There are 2 lines L1 and L2. Messages are message1...message 9. 
( >=V3.0 , M9 is guiding message).

Megavoice is has low power consuption. It operates between 11-60Vdc. The power unit 
has low voltage detection /shut off for lead acid battery systems for 12/24/48 V. Basic 
unit draws only 2.5W normally. Also mains AC/DC power supply can be used and is 
supplied with the unit. 

Megavoice operates in normal office type place. Temerature limit is +5...50C, 0...90% 
RH, normal radiation, normal air pressure, max 1g. Size is 259x195x85 mm and weight 
apx.1 kg.

1

MEGAVOICE 2000 V.3.1 MANUAL V.2000-09-20

Summary of Contents for megavoice 2000

Page 1: ...MEGAVOICE 2000 Duratech Oy Model code 6000 2003 Version 000 31 00 01 MULTIPURPOSE TELECOMPUTER INSTALLATION MANUAL MEGAVOICE 2000 V 3 1 MANUAL V 2000 09 20 www duratech net...

Page 2: ......

Page 3: ...5 4 RECORD 2 13 5 5 PLAY 3 13 5 6 MODE SWITCHING 40 41 42 43 44 14 5 7 RESET INCOMING CALL COUNTERS 45 14 5 8 NOTE 14 5 10 LINE TYPE 50 51 15 5 11 LINE MESSAGE 52 53 16 5 12 LINE LEVEL 54 55 16 5 13 L...

Page 4: ......

Page 5: ...ption for E M lines Basic system has line interfaces for headset and CD player or recorder The line level is adjustable from the front panel The front panel dip switches are used for special cases and...

Page 6: ...icators Green Yellow red functions OK wait error Recording level meter low satisfactory too high Front panel switched Sw1 Sw8 Control special functions normally not used A expansion place for display...

Page 7: ...le 2 Line 2 pin Pair Color Signal 10 4 Teleline a wire 11 Red 22 5 Yellow 23 Black 14 6 Blue M input 15 White E output POWER CABLE 2 4 wires flat cable 0 14 mm Power connector 2 1 mm female DC connect...

Page 8: ...ut Mouth Start V control input 8 60 V 2 Red 1 line E output Earth Busy V coltage out 2 60V POWER CABLE 2 4 wires flat cable 0 14 mm Power connector 2 1 mm female DC connector middle contact V Connecte...

Page 9: ...ntinous message on E M lines E wire indicates when the message is on and a short off state when the message starts again 1 8 EXAMPLE 4 CONTINOUS MESSAGE AND REMOTE PROGRAMMING Line 1 has CTI circuit C...

Page 10: ...the extention of the operator 57 1 5 There is a 5x5 s delayed answer Line 2 is set up 50 2 128 1 50 2 128 2 502 128 3 502 128 4 All modes has MOH 66 Setup is stored Message 1 2 and 3 are recorded Era...

Page 11: ...ead set mic connected directly to Megavoice with line level 0 8 V interface from CD or recorded or PC The operations are controlled in all cases using line 1 with a DTMF telephone The levels or the mi...

Page 12: ...sed V 0 can be used Megavoice answers with OK beeps If not try call again 4 Play an old message 1 Dial command V 3 1 Device plays back message 1 This way m message is played back with V 3 m command st...

Page 13: ...__________________________________ _______________________________________________________________________ MESSAGE 5 _______________________________________________________________________ ___________...

Page 14: ...BER 562 ____________________ ANSWER DELAY RINGS 572 _____________ 1 LINE INTERFACE TELELINE ______ 600 ohm_______ E M _______ SYSTEM Flash time x 10ms 59 1 __________ 12 Delay flash number x 100ms 59...

Page 15: ...n state and exits it when swithed off it V V A picture of the mode switch 3 6 DAY NIGHT CONTROL Megavoice 2000 can be also set into day night vacation mode by remote control if the mode switch is not...

Page 16: ...counters are backed up every 24h Remote mode changes are immediately stored Megavoice has 1 lines They have 4 modes Day night vacation programming There are 9 possible messages During installation the...

Page 17: ...the Mode Switch is in Program state THEN the line is hung up if the switch is changed into other state Useful to exit the programming state 5 3 ERASE MESSAGE 1 1 m m message number 1 muodossa If m cl...

Page 18: ...ing state 42 111 sets all lines into night mode without entering the programming state 43 111 sets all lines into vacation mode The front panel mode switch is connected to sw1 and sw2 M1 input sets sw...

Page 19: ...on E M on state L1 do not switch teleline or 600 om line ON for CTI line Example Ready types Type tt Description 0 153 Continuous message on CTI line answer on 1 line call 1 144 Continous message E M...

Page 20: ...number is high sensitivity c Line number 1 6 n digit 1 9 One number is 3 dB If display the value Default output level is 8 and input is 6 8 ja sis n 6 The level meter is adjusted with these values Th...

Page 21: ...ms Flash time 02 10 100 ms 10 x100ms 1s Delay bw last DTMF digit and release 03 12 100 ms 20 x100ms 1 2 s Start delay before a message 04 03 number Mode switch 05 01 number SW mode MV 01 Used setting...

Page 22: ...type V 7 pppppp wait for OK pppppp password with 6 digits Default value is not here but written in 3 4 This command must be entered twice If password is 000000 password is no longer used Programming s...

Page 23: ...shed Stop the message and Switch teleline ON Wait 0 8 s Make a flash Wait for time delay par 02 Default is 1s Dial the transfer target number Release teleline and E wire off Return to START Is there t...

Page 24: ...UING SYSTEM MEGAVOICE Extention group Attendant Transfer Transfer Over flow Preanswer system 1 2 Queuining system 3 6 Answer Answer 1 2 3 4 5 6 ANNEX 2 Transferring machine example 1 20 MEGAVOICE 2000...

Page 25: ...rring machine example 2 TRANSFERRING MACHINE PREANSWER and QUEUING SYSTEM MEGAVOICE Extention group Transfer Transfer Over flow Preanswer 1 2 Queiung 3 5 Answer Answer 1 3 4 5 2 MEGAVOICE 2000 V 3 1 M...

Page 26: ...fety EN 60950 1992 A1 1992 A2 1993 A3 1995 EMC EN 50081 1 1992 ja EN 55022 Class B EN 50082 1 1997 ja EN 55024 1998 Tele interface TBR21 1998 EN300001 1996 applied in some parts The interface is espec...

Reviews: