Duratech megavoice 2000 Installation Manual Download Page 17

5. MEGAVOICE COMMANDS V.3.0

This expains the different commands. First is syntax, then fields are explained, then notes.

5.1 LOGIN INTO PROGRAMMING STATE  0

    0  n  n  n  n  n  n   #    OR      0   #   if password is not used. Read notice.

,nnnnnn=password with 6 numbers. Default nnnnnn= <is not written here, see 3.4>.

Display : Before command "Login".
Device : Line 1 is called. Some PABX require that a function code is now entered to start 
DTMF-sending. It is stated is the PABX manuals. Wait for megavoice answer. 
Dial  0 nnnnnn #. Megavoice sends  OK-beeps, green led is lid and the display indicated 
"Enter command". The message of the line is halted. When megavoice answers the line, it 
waits for 2 second before it starts its message. Dial this comand immediately the Megavoice 
answers. The Spoken message wmay interface with the Dual-Tone-codes.Eg.   0 123456 #. 

Note :

 If mode switch is activated with * 594* 3# (as default )and the device is in PROGRAM-

state,  0 # is not used for login. Megavoice answers then and goes directly into programming 
state and gives 2 beeps= OK

5.2 LOGOUT OF THE PROGRAMMING STATE 0

    0   #  
When used during programming, program exits the programming state and hangs up.
Display indicates "logout " followed by "login".  Eg.   0 #.

Note :

  If  Mode Switch is activated by   594 2# or  594 3# commands AND the Mode 

Switch is in Program-state, THEN the line is hung up if the switch is changed into other state. 
Useful to exit the programming state.

5.3 ERASE MESSAGE 1

    1  m #
m= message number 1... muodossa. If m=

 clear all messages (= command  1

#).

Default is all messages empty. Guiding message 9( and all) can be erased only if sw8 is 
1=down.
Megavoice : Beeps once for every 8 s erased. When ready beeps  twice as OK-tone. Error 
tone (9-beeps) is given when there is an error.  Eg. Erase message 1 is   1 1 #.

5.4  RECORDING MESSAGE 2

    2  m #
m= message number 1...9
Megavoice : Gives one beep 2 s after this comend to indicate start of recording. Recoring is 
stopped with # command or with 9-beeps error tone is memory is full or message is not 
empty. # beep is not recorded.
The front panel leds acts as UV level meter. The red led may occasionally flash during 
recording. Recordings are stored into chip memory for 20 years. See also chapter Recoring. 
Message must be erased before recording a new one. Eg.  Record msg 1 is   2 1 # 
Eg

5.5  PLAY MESSAGE  3

    3  m  #

m= Message number 1...9 . Command plays back a recorded message.
megavoice : Gives on wait-beep and play message mm , ends with wait -beep, and gives 
OK-beeps.
Display indicates the number of the message. Play back can be halted with #.
Eg. Play message 1 is   3 1 #. Play message 2 is  3 2 #
 

V

V

V

V

V

V

V

V

VV

V V 

V

V

 Dial  

2 1 #, wait for a beep,  record and stop with #. Play back it with  

V

 3 1#. (See 5.5)

V

V

13

MEGAVOICE 2000 V.3.1 MANUAL V.2000-09-20

Summary of Contents for megavoice 2000

Page 1: ...MEGAVOICE 2000 Duratech Oy Model code 6000 2003 Version 000 31 00 01 MULTIPURPOSE TELECOMPUTER INSTALLATION MANUAL MEGAVOICE 2000 V 3 1 MANUAL V 2000 09 20 www duratech net...

Page 2: ......

Page 3: ...5 4 RECORD 2 13 5 5 PLAY 3 13 5 6 MODE SWITCHING 40 41 42 43 44 14 5 7 RESET INCOMING CALL COUNTERS 45 14 5 8 NOTE 14 5 10 LINE TYPE 50 51 15 5 11 LINE MESSAGE 52 53 16 5 12 LINE LEVEL 54 55 16 5 13 L...

Page 4: ......

Page 5: ...ption for E M lines Basic system has line interfaces for headset and CD player or recorder The line level is adjustable from the front panel The front panel dip switches are used for special cases and...

Page 6: ...icators Green Yellow red functions OK wait error Recording level meter low satisfactory too high Front panel switched Sw1 Sw8 Control special functions normally not used A expansion place for display...

Page 7: ...le 2 Line 2 pin Pair Color Signal 10 4 Teleline a wire 11 Red 22 5 Yellow 23 Black 14 6 Blue M input 15 White E output POWER CABLE 2 4 wires flat cable 0 14 mm Power connector 2 1 mm female DC connect...

Page 8: ...ut Mouth Start V control input 8 60 V 2 Red 1 line E output Earth Busy V coltage out 2 60V POWER CABLE 2 4 wires flat cable 0 14 mm Power connector 2 1 mm female DC connector middle contact V Connecte...

Page 9: ...ntinous message on E M lines E wire indicates when the message is on and a short off state when the message starts again 1 8 EXAMPLE 4 CONTINOUS MESSAGE AND REMOTE PROGRAMMING Line 1 has CTI circuit C...

Page 10: ...the extention of the operator 57 1 5 There is a 5x5 s delayed answer Line 2 is set up 50 2 128 1 50 2 128 2 502 128 3 502 128 4 All modes has MOH 66 Setup is stored Message 1 2 and 3 are recorded Era...

Page 11: ...ead set mic connected directly to Megavoice with line level 0 8 V interface from CD or recorded or PC The operations are controlled in all cases using line 1 with a DTMF telephone The levels or the mi...

Page 12: ...sed V 0 can be used Megavoice answers with OK beeps If not try call again 4 Play an old message 1 Dial command V 3 1 Device plays back message 1 This way m message is played back with V 3 m command st...

Page 13: ...__________________________________ _______________________________________________________________________ MESSAGE 5 _______________________________________________________________________ ___________...

Page 14: ...BER 562 ____________________ ANSWER DELAY RINGS 572 _____________ 1 LINE INTERFACE TELELINE ______ 600 ohm_______ E M _______ SYSTEM Flash time x 10ms 59 1 __________ 12 Delay flash number x 100ms 59...

Page 15: ...n state and exits it when swithed off it V V A picture of the mode switch 3 6 DAY NIGHT CONTROL Megavoice 2000 can be also set into day night vacation mode by remote control if the mode switch is not...

Page 16: ...counters are backed up every 24h Remote mode changes are immediately stored Megavoice has 1 lines They have 4 modes Day night vacation programming There are 9 possible messages During installation the...

Page 17: ...the Mode Switch is in Program state THEN the line is hung up if the switch is changed into other state Useful to exit the programming state 5 3 ERASE MESSAGE 1 1 m m message number 1 muodossa If m cl...

Page 18: ...ing state 42 111 sets all lines into night mode without entering the programming state 43 111 sets all lines into vacation mode The front panel mode switch is connected to sw1 and sw2 M1 input sets sw...

Page 19: ...on E M on state L1 do not switch teleline or 600 om line ON for CTI line Example Ready types Type tt Description 0 153 Continuous message on CTI line answer on 1 line call 1 144 Continous message E M...

Page 20: ...number is high sensitivity c Line number 1 6 n digit 1 9 One number is 3 dB If display the value Default output level is 8 and input is 6 8 ja sis n 6 The level meter is adjusted with these values Th...

Page 21: ...ms Flash time 02 10 100 ms 10 x100ms 1s Delay bw last DTMF digit and release 03 12 100 ms 20 x100ms 1 2 s Start delay before a message 04 03 number Mode switch 05 01 number SW mode MV 01 Used setting...

Page 22: ...type V 7 pppppp wait for OK pppppp password with 6 digits Default value is not here but written in 3 4 This command must be entered twice If password is 000000 password is no longer used Programming s...

Page 23: ...shed Stop the message and Switch teleline ON Wait 0 8 s Make a flash Wait for time delay par 02 Default is 1s Dial the transfer target number Release teleline and E wire off Return to START Is there t...

Page 24: ...UING SYSTEM MEGAVOICE Extention group Attendant Transfer Transfer Over flow Preanswer system 1 2 Queuining system 3 6 Answer Answer 1 2 3 4 5 6 ANNEX 2 Transferring machine example 1 20 MEGAVOICE 2000...

Page 25: ...rring machine example 2 TRANSFERRING MACHINE PREANSWER and QUEUING SYSTEM MEGAVOICE Extention group Transfer Transfer Over flow Preanswer 1 2 Queiung 3 5 Answer Answer 1 3 4 5 2 MEGAVOICE 2000 V 3 1 M...

Page 26: ...fety EN 60950 1992 A1 1992 A2 1993 A3 1995 EMC EN 50081 1 1992 ja EN 55022 Class B EN 50082 1 1997 ja EN 55024 1998 Tele interface TBR21 1998 EN300001 1996 applied in some parts The interface is espec...

Reviews: