30
C M F - 8 3 0
O P E R A T I N G I N S T R U C T I O N S
4.1
Lubrication cont.
Wheel bearings:
repack annually
Gearbox:
Grease 20‑30 pumps every 250 hours (each gearbox), located on the bottom of the tub in front of the left
tires.
Chains:
Oil conveyor chains every 15 hours.
When to change oil in gearboxes:
•
After the first 50‑100 hours of operation, drain initial oil, preferably when box is warm. There after
oil should be changed every 1500 hours or 12 months, whichever comes first. If machine usage is
severe or more than 10 loads per day, it is advisable to change the oil every 1000 hours or 6 months.
Inspect and wash oil reservoir breather cap as needed. Air dry before reinstalling.
Fill each gearbox
with approximately 5 ½ gallons (21 L) of EP150 or 80w-90 GL-5 weight Gear Lube.
RR-USA
recommends using synthetic oil in their gearbox.
Monitor the oil level in the reservoir daily. Oil level
should be in the middle of the sight gauge. The working temperature must not exceed (90 degrees C) 194
degrees F max. Proper lubrication is essential for efficient running and long life of the unit as a whole. It
is also important to select the correct type of oil to ensure the long life of the gear reducer.
Procedure for changing oil in gearboxes (
see chart 4.1 on the following page
):
1.
Remove magnetic drain plug from the bottom of the right angle gearbox and clean the magnet if it has
any metal on it. Return plug to the gearbox before filling.
2.
Disconnect the lube lines from the top of the gearboxes at the tee fitting. Disconnect the other lube lines
from the bottom of the gearboxes at the other tee.
3.
To fill, connect (‑8)3/4” MJIC fitting to hose connected to the right angle box and place overflow hose in
a pan. Pump oil into the gearbox until it runs out of the overflow hose. Reconnect hoses to the correct
fitting. Repeat for rear gearbox.
4.
Fill reservoir and continue to monitor reservoir levels during operation so that oil remains half‑way up in
sight gauge or higher, allow for more expansion in warmer climates.
5.
Two‑speed gearbox should be half full of oil so that oil is present in sight gauge. Follow same
maintenance schedule and use the same oils as recommended above for vertical gearboxes.
6.
Any brand of 80w‑90 gear oil with a GL‑5 rating may also be used;
RR_USA recommends use of
synthetic oils.
Recommendation:
Prior to starting each day it is advisable to check the oil level of gearboxes at the sight gauge.
Contact information for:
ConocoPhillips Lubricants:
Telephone: 1‑800‑255‑9556 (Technical Hotline)
Email: [email protected]
Do not dispose of gearbox oil in the municipal waste stream
Summary of Contents for HAYBUSTER CMF-830
Page 2: ...A Tradition of Innovation Since 1966...
Page 4: ...A Tradition of Innovation Since 1966...
Page 49: ...35 C M F 8 3 0 O P E R A T I N G I N S T R U C T I O N S 6 5 Dogleg Conveyor...
Page 53: ...39 C M F 8 3 0 O P E R A T I N G I N S T R U C T I O N S...
Page 54: ...40 C M F 8 3 0 O P E R A T I N G I N S T R U C T I O N S A Tradition of Innovation Since 1966...
Page 55: ...CMF 830 VERTICAL MIXER Part 2 Parts Reference TM 41...
Page 64: ...50 C M F 8 3 0 P A R T S R E F E R E N C E T U B L I N E R A S S E M B L Y...
Page 66: ...52 C M F 8 3 0 P A R T S R E F E R E N C E M A I N F R A M E A S S E M B L Y...
Page 138: ...124 C M F 8 3 0 P A R T S R E F E R E N C E H Y D R A U L I C T A N K A S S E M B L Y...
Page 146: ...132 C M F 8 3 0 P A R T S R E F E R E N C E G E A R B O X H Y D R A U L I C S C H E M A T I C...
Page 154: ...140 C M F 8 3 0 P A R T S R E F E R E N C E A Tradition of Innovation Since 1966...
Page 156: ...142 C M F 8 3 0 P A R T S R E F E R E N C E O R B I T M O T O R S 3 9 0 0 0 2 5 3 9 0 0 0 3 2...
Page 158: ...144 C M F 8 3 0 P A R T S R E F E R E N C E H Y D R A U L I C C Y L I N D E R A S S E M B L Y...
Page 162: ...148 C M F 8 3 0 P A R T S R E F E R E N C E A Tradition of Innovation Since 1966...
Page 164: ...150 C M F 8 3 0 P A R T S R E F E R E N C E H U B A N D S W I V E L A X L E...