background image

 

 

Instruction Manual 

PES1513 Electric Power Unit - V1.1 

www.durapac.com 

Page 2 of 8 

 

 

This is a safety alert symbol. It is used to alert you to potential personal injury hazards. 
Obey all safety messages that follow this symbol to avoid injury or death 

1.0

 

Product Information 

DURAPAC – 15 Series Auto 2 Speed Power Units are engineered to meet Industrial Standards for 
Performance and Safety. They feature a two speed pump delivering 9.5 Lpm up to 65 bar and 1.1 
Lpm up to 700 bar pressure. The power unit has a 3 way solenoid valve and remote pendant to 
actuate advance/hold/retract functions on single acting cylinders and tools. The power unit is driven 
by a 1.5 kW 240 Volt/50 Hz single phase electric motor and is ideal for operating medium to large 
tonnage cylinders and systems.  

Special skill, knowledge and training may be required for a specific task and the product may not be 
suitable for all jobs. The user must ultimately make the decision regarding suitability of the product 
for any given task and assume the responsibility of safety for all in the work area. Contact a Durapac 
representative if you are unsure of your power unit’s suitability for a particular application. 

2.0

 

Receiving Instructions 

It is recommended prior to use that an inspection be done by qualified personnel and that any 
missing or damaged parts, decals, warning/safety labels or signs are replaced with Durapac 
authorised replacement parts only. Any power unit that appears to be damaged in any way, is worn, 
leaking or operates abnormally should be removed from service immediately until such time as 
repairs can be made. Any power unit that has been or suspected to have been subject to a shock 
load should be removed from service immediately until inspected by a Durapac authorised service 
centre. Owners and operators of this equipment should be aware that the use and subsequent 
repair of this equipment may require specialised training and knowledge. 

3.0

 

Safety 

Save these instructions. For your safety, read and understand the information contained within. The 
owner and operator should have an understanding of this product and safe operating procedures 
before attempting to use this product. Instructions and safety information should be conveyed in the 
operator's native language before use of this product is authorised. Make certain that the operator 
thoroughly understands the inherent dangers associated with the use and misuse of the product. If 
any doubt exists as to the safe and proper use of this product as outlined in this factory authorised 
manual, remove from service immediately. 

 

DANGER: 

 

 

To avoid personal injury keep hands and feet away from work area during operation 

 

 

Do NOT 

handle pressurised hoses. Escaping oil under pressure can penetrate the skin 

causing serious injury. If oil is injected under the skin, see a doctor immediately 

 

 

Stay clear of loads supported by hydraulics. A cylinder, when used as a load lifting 
device, should never be used as a load holding device. After the load has been raised 
or lowered, it must always be blocked mechanically 

Summary of Contents for PES1513

Page 1: ...2 186 Granite Street GEEBUNG QLD 4034 Australia sales absoluteequipment com au Phone 61 7 3865 4006 Fax 61 7 3102 6288 Maximum Operating Pressure 700 bar Instruction Manual 15 Series Auto 2 Speed Electric Power Unit Model PES1513 ...

Page 2: ... Any power unit that appears to be damaged in any way is worn leaking or operates abnormally should be removed from service immediately until such time as repairs can be made Any power unit that has been or suspected to have been subject to a shock load should be removed from service immediately until inspected by a Durapac authorised service centre Owners and operators of this equipment should be...

Page 3: ...erator is responsible for this activity towards other persons Do NOT lift hydraulic equipment by the hoses or couplers Use the carrying handle or other means of safe transport Hydraulic equipment must only be serviced by a qualified hydraulic technician For repair service contact the Durapac authorised service centre in your area To protect your warranty use only high quality hydraulic oil CAUTION...

Page 4: ... contact with corrosive materials such as battery acid creosote impregnated objects and wet paint Never paint a coupler or hose FAILURE TO HEED THESE WARNINGS MAY RESULT IN PERSONAL INJURY AS WELL AS PROPERTY DAMAGE 4 0 Installation IMPORTANT Always secure threaded port connections with high grade non hardening pipe thread sealant Teflon tape can be used if only one layer of tape is used and it is...

Page 5: ...r press the arrow on the remote pendant Fluid will flow from A port to tank 5 4 Pressure Adjustment The directional control valve subplate is fitted with an adjustable pressure relief valve The operator can dial in the maximum desired pressure required for the application at hand The pressure adjusting range is from 0 700 bar 6 0 Maintenance IMPORTANT Check oil level regularly Use only good qualit...

Page 6: ...leed air from system if necessary 6 1 5 Wipe up any spilled fluid and reinstall the air vent plug reservoir cap 6 2 Bleeding Air from the System 6 2 1 Repeat Steps 6 1 1 to 6 1 3 above if required 6 2 2 Invert cylinder and place at a lower level than the power unit reservoir 6 2 3 Extend and retract the cylinder several times without putting a load on the system Air will be released into the power...

Page 7: ... to 6 1 Adding Hydraulic Fluid Fill and bleed the system Power unit runs but will not pump oil Power unit is not primed Run power unit a few minutes tipping from side to side Externally adjustable relief valve is not correctly set Reset the relief valve to appropriate level Damaged o ring Send to a Durapac authorised service centre for repair Defective control valve Send to a Durapac authorised se...

Page 8: ...ill and bleed the system Application responds to pressurised fluid but system does not maintain pressure Leaky connection Clean reseal with thread sealant and tighten connection Leaking cylinder seals Replace worn seals Look for excessive contamination or wear Replace contaminated fluid Power unit or valve not operating correctly Contact a Durapac authorised service centre for repair Overload cond...

Reviews: