Instruction Manual
PES1513 Electric Power Unit - V1.1
www.durapac.com
Page 4 of 8
Do NOT
connect power unit to a hydraulic system that is powered by another pump
3.2
Hydraulic Hoses & Fluid Transmission Lines
Avoid short runs of straight line tubing. Straight line runs do not provide for expansion
and contraction due to pressure and/or temperature changes
Reduce stress in tube lines. Long tubing runs should be supported by brackets or clips.
Before operating the power unit, connections should be tightened securely and leak-
free. Over tightening can cause premature thread failure or high pressure fittings to
burst
Should a hydraulic hose ever rupture, burst or need to be disconnected, immediately
shut off the power unit and release all pressure. Never attempt to grasp a leaking
pressurised hose with your hands. The force of escaping hydraulic fluid can inflict
injury
Do NOT
subject the hose to potential hazard such as fire, sharp objects, extreme heat
or cold or heavy impact
Do NOT
allow the hose to kink, twist, curl, crush, cut or bend so tightly that the fluid
flow within the hose is blocked or reduced. Periodically inspect the hose for wear
Hose material and coupler seals must be compatible with the hydraulic fluid used.
Hoses also must not come in contact with corrosive materials such as battery acid,
creosote-impregnated objects and wet paint. Never paint a coupler or hose
FAILURE TO HEED THESE WARNINGS MAY RESULT IN PERSONAL INJURY AS WELL AS PROPERTY DAMAGE.
4.0
Installation
IMPORTANT:
Always secure threaded port connections with high grade, non-hardening pipe
thread sealant. Teflon tape can be used if only one layer of tape is used and it is applied
carefully, two threads back, to prevent the tape from being introduced into hydraulic system,
which could cause jamming of precision-fit parts
4.1
Familiarise yourself with the specifications and illustrations in this owner’s manual.
Know your power unit, its limitations and how it operates before attempting to use.
Refer to the specification chart below or if in doubt, contact a Durapac representative.
4.2
Check all system fittings and connections to be sure they are tight and leak free.
4.3
Check oil level in reservoir before operating power unit.
4.4
Ensure a
clockwise motor rotation
when motor is viewed from the fan end.
4.5
Remove air from the cylinder – Position the cylinder so that the piston rod is pointed
down and the cylinder is lower than the pump. Advance and retract the cylinder
65 bar 700 bar
PES1513 1.5
240
50 8.3
10
700
9.5
1.1
Solenoid Adv/Hold/Retract
S/A
59
Used
with
Cylinder
Maximum
Pressure
Rating
(bar)
Flow Rate
(Lpm)
Remote Pendant Function
4 mtr
Dry
Weight
(kg)
Model
Number
kW
Voltage
(1 Phase)
Hz Amps
Usable Oil
Capacity
(L)