background image

 

 

Instruction Manual 

DPA-15D Air Hyd. Power Unit - V1.5 

www.durapac.com 

Page 3 of 10 

 

causing serious injury. If oil is injected under the skin, see a doctor immediately 

 

 

Stay clear of loads supported by hydraulics. A cylinder, when used as a load lifting 
device, should never be used as a load holding device. After the load has been raised 
or lowered, it must always be supported mechanically 

 

WARNING: 

 

 

The system operating pressure must not exceed the pressure rating of the lowest 
rated component in the system. Install pressure gauges in the system to monitor 
operating pressure. It is your window to what is happening in the system 

 

 

Always wear appropriate 

personal protective equipment 

(

PPE

) when operating 

hydraulic equipment. The operator must take precaution against injury due to failure 
of the tool or work piece(s) 

 

 

Do NOT

 hold or stand directly in line with any hydraulic connections while pressurising 

 

 

Do NOT

 attempt to disconnect hydraulic connections under pressure. Release all line 

pressure before disconnecting hoses

 

 

 

All personnel must be clear before lowering load or depressurising the system

 

 

 

Do NOT

 attempt to lift a load weighing more than the capacity of the cylinder 

 

IMPORTANT: 

 

 

If at any stage, the safety related decals become hard to read, these must be replaced 

 

 

Minimum age of the operator must be 18 years. The operator must have read and 
understood all instructions, safety issues, cautions and warnings before starting to 
operate the equipment. The operator is responsible for this activity towards other 
persons 

 

 

Do NOT

 lift hydraulic equipment by the hoses or couplers. Use the carrying handle or 

other means of safe transport

 

 

 

Hydraulic equipment must only be serviced by a qualified hydraulic technician. For 
repair service, contact the Durapac authorised service centre in your area. To protect 
your warranty, use only high quality hydraulic oil

 

 

CAUTION: 

 

 

KEEP HYDRAULIC EQUIPMENT AWAY FROM FLAMES AND HEAT.

 Hydraulic fluid can 

ignite and burn. Excessive heat will soften packings and seals, resulting in fluid leaks. 
Heat also weakens hose materials and packings. For optimum performance do not 
expose equipment to temperatures of 65°C (150°F) or higher. Protect all equipment 
from weld spatter 

 

 

No alteration should be made to this device 

3.1

 

Hydraulic Power Units 

 

Do

 use a gauge or other load measuring instrument to verify load 

 

Do NOT

 exceed the rated capacity of the power unit or any equipment in the system. 

Burst hazard exists if connection pressure exceeds rated pressure 

 

Do NOT

 operate the system with bent or damaged couplers or damaged threads 

Summary of Contents for DPA-15D

Page 1: ...2 186 Granite Street GEEBUNG QLD 4034 Australia sales absoluteequipment com au Phone 61 7 3865 4006 Fax 61 7 3102 6288 Maximum Operating Pressure 700 bar Instruction Manual Reciprocating Air Hydrauli...

Page 2: ...ty for a particular application 2 0 Receiving Instructions It is recommended prior to use that an inspection be done by qualified personnel and that any missing or damaged parts decals warning safety...

Page 3: ...ORTANT If at any stage the safety related decals become hard to read these must be replaced Minimum age of the operator must be 18 years The operator must have read and understood all instructions saf...

Page 4: ...objects extreme heat or cold or heavy impact Do NOT allow the hose to kink twist curl crush cut or bend so tightly that the fluid flow within the hose is blocked or reduced Periodically inspect the ho...

Page 5: ...n reservoir before operating power unit 5 0 Operation IMPORTANT Always monitor pressure load or position using suitable equipment Pressure may be monitored by means of an optional manifold and gauge L...

Page 6: ...power unit hose and application We recommend Durapac Hydraulic Oil or equivalent Equipment must only be serviced by a qualified hydraulic technician For repair service contact your local Durapac autho...

Page 7: ...han the power unit reservoir 6 2 3 Extend and retract the cylinder several times without putting a load on the system Air will be released into the power unit reservoir 6 2 4 Recheck oil level after r...

Page 8: ...ng application connection Replace application connection Application responds slower than normal Loose connection or coupler Tighten connection or coupler Restricted hydraulic line or fitting Clean an...

Page 9: ...V1 5 www durapac com Page 9 of 10 Note Not all components of the power unit are replacement items but are illustrated as a convenient reference of location and position in the assembly sequence 8 0 Pa...

Page 10: ...1036 2 53 O ring ZBN1000 3 16 Screw ZBN1140 2 54 Compressing spring ZBN1066 1 17 Handle ZBN1141 1 55 Screw ZBN1067 1 18 Pad A ZBN1142 1 56 Air entrance cover ZBN1068 1 19 O ring ZBN1037 2 57 O ring ZB...

Reviews: