background image

 

 

Instruction Manual 

DPA-15D Air Hyd. Power Unit - V1.5 

www.durapac.com 

Page 2 of 10 

 

 

This is a safety alert symbol. It is used to alert you to potential personal injury hazards. 
Obey all safety messages that follow this symbol to avoid injury or death 

1.0

 

Product Information 

DURAPAC – Double Acting Reciprocating Air Hydraulic Power Units are engineered to meet Industrial 
Standards for Performance and Safety. The DPA-15D model is an air hydraulic power unit with a 4-
way valve. Its unique hydraulic circuit allows the quick displacement of hydraulic fluid under no load 
conditions and easy pumping in loaded conditions. These air actuated pumps supply compressed 
hydraulic fluid to a compatible double-acting cylinder, anywhere that 700 bar of fluid pressure is 
needed.  

 

4 way directional control valve to operate double acting cylinders 

 

1.5 L usable oil reservoir 

 

3 position valve for adv/hold/retract functions 

 

Dust cover protection for the release control valve 

 

Convenient carry handle included 

 

Recommended air pressure range 4-12 bar 

Special skill, knowledge and training may be required for a specific task and the product may not be 
suitable for all jobs. The user must ultimately make the decision regarding suitability of the product 
for any given task and assume the responsibility of safety for all in the work area. Contact a Durapac 
representative if you are unsure of your power unit’s suitability for a particular application. 

2.0

 

Receiving Instructions 

It is recommended prior to use that an inspection be done by qualified personnel and that any 
missing or damaged parts, decals, warning/safety labels or signs are replaced with Durapac 
authorised replacement parts only. Any power unit that appears to be damaged in any way, is worn, 
leaking or operates abnormally should be removed from service immediately until such time as 
repairs can be made. Any power unit that has been or suspected to have been subject to a shock 
load should be removed from service immediately until inspected by a Durapac authorised service 
centre. Owners and operators of this equipment should be aware that the use and subsequent 
repair of this equipment may require specialised training and knowledge. 

3.0

 

Safety 

Save these instructions. For your safety, read and understand the information contained within. The 
owner and operator should have an understanding of this product and safe operating procedures 
before attempting to use this product. Instructions and safety information should be conveyed in the 
operator's native language before use of this product is authorised. Make certain that the operator 
thoroughly understands the inherent dangers associated with the use and misuse of the product. If 
any doubt exists as to the safe and proper use of this product as outlined in this factory authorised 
manual, remove from service immediately. 

 

DANGER: 

 

 

To avoid personal injury keep hands and feet away from work area during operation 

 

 

Do NOT 

handle pressurized hoses. Escaping oil under pressure can penetrate the skin 

Summary of Contents for DPA-15D

Page 1: ...2 186 Granite Street GEEBUNG QLD 4034 Australia sales absoluteequipment com au Phone 61 7 3865 4006 Fax 61 7 3102 6288 Maximum Operating Pressure 700 bar Instruction Manual Reciprocating Air Hydrauli...

Page 2: ...ty for a particular application 2 0 Receiving Instructions It is recommended prior to use that an inspection be done by qualified personnel and that any missing or damaged parts decals warning safety...

Page 3: ...ORTANT If at any stage the safety related decals become hard to read these must be replaced Minimum age of the operator must be 18 years The operator must have read and understood all instructions saf...

Page 4: ...objects extreme heat or cold or heavy impact Do NOT allow the hose to kink twist curl crush cut or bend so tightly that the fluid flow within the hose is blocked or reduced Periodically inspect the ho...

Page 5: ...n reservoir before operating power unit 5 0 Operation IMPORTANT Always monitor pressure load or position using suitable equipment Pressure may be monitored by means of an optional manifold and gauge L...

Page 6: ...power unit hose and application We recommend Durapac Hydraulic Oil or equivalent Equipment must only be serviced by a qualified hydraulic technician For repair service contact your local Durapac autho...

Page 7: ...han the power unit reservoir 6 2 3 Extend and retract the cylinder several times without putting a load on the system Air will be released into the power unit reservoir 6 2 4 Recheck oil level after r...

Page 8: ...ng application connection Replace application connection Application responds slower than normal Loose connection or coupler Tighten connection or coupler Restricted hydraulic line or fitting Clean an...

Page 9: ...V1 5 www durapac com Page 9 of 10 Note Not all components of the power unit are replacement items but are illustrated as a convenient reference of location and position in the assembly sequence 8 0 Pa...

Page 10: ...1036 2 53 O ring ZBN1000 3 16 Screw ZBN1140 2 54 Compressing spring ZBN1066 1 17 Handle ZBN1141 1 55 Screw ZBN1067 1 18 Pad A ZBN1142 1 56 Air entrance cover ZBN1068 1 19 O ring ZBN1037 2 57 O ring ZB...