1 Important Notes 

 

1.1 Product  

 
This manual describes the installation, commissioning, and maintenance of the POWER CENTER HUB.

 

 

1.2 Target Group 

 
This manual is only for qualified technicians, who have been trained or have demonstrated skills to install 
and maintain this product under the guide of this document for safety purposes. 
 

2 Safety 

 

2.1 Important Safety Instructions 

 

This product is designed and tested according to international safety requirements. The  installer  must  read 
and  follow  all  instructions,  cautions  and  warnings  in  this installation manual. 

 

All  operations  including  transport,  installation,  start-up  and  maintenance,  must  be  carried  out  by qualified, 
trained personnel. 

Before installation, check the unit to ensure free of any transport or handling damage, which could affect insulation 
integrity or safety clearances. Choose the installation location carefully and adhere to specified cooling requirements. 
Unauthorized removal of necessary protections, improper use, incorrect installation and operation may lead to serious 
safety and shock hazards or equipment damage. 

Do  not  install  the  equipment  in  adverse  environment  conditions  such  as  flammable,  explosive, corrosive, 
extreme  high  or  low  temperature,  and  humidity.  Do  not  use  the  equipment  when  the  safety devices do not work 
or disabled. 

Do not use the equipment if any operating anomalies are found. Avoid temporary repairs. 

All  repairs  should  be  carried  out  using  only  qualified  spare  parts,  which  must  be  installed  in  accordance  with 
their  intended  use  and  by  a  licensed  contractor  or  authorized  Power  service representative. 

Power  accepts no liability for damage from incorrect or improper operation. 

 
 

2.2 Explanation of Symbols 

 

Symbol 

Usage 

 

Disposal:

 Equipment that has reached the end of its life must be collected separately and returned to an 

approved recycling facility. Any device no longer required must be returned to an authorized dealer or 
approved collection and recycling facility.

 

 

Caution:

 Indicates directions which must be fully understood and followed in entirety in order to avoid 

potential safety hazards including equipment damage or personal injury.

 

 

Note: 

Indicates that the reader should stop, use caution and fully understand the operations explained 

before proceeding.

 

 

FCC mark  

The inverter complies with the requirements of part 15 of FCC rules.

 

 

 

 

Summary of Contents for PC-PRO-WIFI

Page 1: ...POWER CENTER USER MANUAL Model PC PRO WIFI For use with Duracell Power Center Microinverters...

Page 2: ...4 Locating the Power Center Hub 4 4 1 Installing the antennas 4 4 2 Proximity to the PV array 4 4 3 Proximity to the customer supplied internet router 4 4 4 Mapping the Power Center Hub to the PV arra...

Page 3: ...ent damage Do not install the equipment in adverse environment conditions such as flammable explosive corrosive extreme high or low temperature and humidity Do not use the equipment when the safety de...

Page 4: ...V panels PV port inputs Mutiple gateways can be provisioned where PV arrays exceed this limit 3 1 2 Basic requirements prerequisites 120VAC power outlet required for the POWER CENTER HUB power adapter...

Page 5: ...ons Indicators B Power C Server communication D Microinverter communication E System alarm Other Features A SD card slot N Antenna screw type O Wall bracket P Serial number label Ports F Wi Fi antenna...

Page 6: ...NTER HUB can communicate with the router via hard wired ethernet or Wi Fi The ideal location for microinverter communication may conflict with router communication In the case that the resulting Wi Fi...

Page 7: ...t Modes LED State Description Firmware update Initializing Power ON Server online Internet offline Internet online server offline Local APP connected Microinverter communication OK Microinverter IDs i...

Page 8: ...it s being installed Select Next when completed 5 Select Add DTU ID then scan or manually input the DTU ID Select Next when completed 6 Select Start binding then choose the angle tilt for the PV array...

Page 9: ...etary RF Nordic Maximum distance open space 200m Maximum PV panels 99 Server communication Type WIFI 802 11b g n 1 Ethernet Sample rate 15 minute Mechanical Data Ambient temperature range C 20 C 65 C...

Page 10: ...8 Appendix A Installation Map Template...

Page 11: ...Doc 97016...

Reviews: