UP200-GSM Rev.1.2 08/01/2014
OPERATION
Visitor mode
When the visitor pushes the call button, the device
initiates a voice call to the configured phone number.
If the called party accepts the call, the communication
establishes for the configured duration. During the
call, the connection cannot be interrupted nor by
making a call to the device, nor by pressing the button
again. The call is ended automatically when the
configured communication time expires, or the called
party can hang up the call at anytime on his/her
phone. The call is ended automatically if the called
party does not answer or is not available.
A new call is initiated only if the button is pressed
again.
Listen-in mode
The intercom unit can be called from any phone
number. In this case the unit accepts the call without
ringing and the voice connection establishes. The call
can be ended on the caller’s phone or by pressing the
call button on the unit.
If the call is initiated from a phone number which
is configured in the unit as gate opener number,
the device will consider the call as a gate opening
call. In this case voice connection is not
established, but the relay output is activated.
To make a “listen-in” call from such phone number,
use the
#31#
code in front of the number, this hides
the
caller’s
phone
number
(e.g.:
#31#0036301234567). The unit will already accept the
call received from unknown phone number.
Controlling the relay output
The
RELAY
(normally open, NO) relay output can be
controlled as follows, depending on the usage:
controlling by free call
:
on incoming call, after identifying the caller ID, the
unit rejects the call and activates the output
e.g. garage door or barrier opening, for which max
100 user phone numbers can be configured
controlling by the pushbutton
:
the relay activates when the call button is pushed
e.g. possibility to connect an existing door bell
controlling by the
INPUT
contact input
:
the relay activates on external contact
e.g. garage door opening or closing
controlling by the phone’s:
while in call by pressing 1#
of the phone’s
numbered keys the relay activates for the
configured time period
ATTENTION:
The
RELAY
and
–OUT+
outputs is activated in
parallel and independently from each other by
both menu items, the
Control of outputs
and the
Gate control
. Please take this into consideration
when planning the usage!
Controlling the voltage output
The
–OUT+
voltage output can be controlled as
follows:
controlling by the
INPUT
contact input
:
after activating the input, the output activates for
the configured time period
e.g. optional indoor pushbutton for electric lock
control
controlling by the phone’s keys
:
while in call
by pressing
2#
of the phone’s
numbered keys the output activates for the
configured time period
e.g. direct control of the electric lock
The voltage output is protected against short circuit
and overcurrent, thereby the output turns off upon
overcurrent and becomes operable again after the
termination of the fault.
Forwarding incoming SMS messages
The unit forwards the SMS messages received on its
SIM card (e.g. balance information in case of a
prepaid card) to the configured phone number. After
forwarding, the received message is deleted from the
SIM card. If there is no phone number configured, the
unit deletes the
incoming messages without
forwarding.
Status LED indications
LED
Color
GSM OK
green
Is lit after connecting to the
GSM network and reaching
the sufficient GSM signal.
The sufficient signal is: 10
(on 0-31 scale)
GSM / SIM
ERROR
red
Is lit continuously if the device
cannot connect to the GSM
network.
Possible reasons:
- the GSM antenna is faulty or
is not connected
- the SIM card is not inserted,
- or the PIN code request is
not disabled,
- or the SIM card is faulty.
CALL IN
PROGRESS
green
Communication in progress.
A call or conversation is in
progress.
-OUT+
red
Voltage output activated
RELAY
red
Relay output activated