DUPLOMATIC
E.M.6427 RELEASE 7.1 05-03
6427071-230-en 11
OPERATING FUNCTION N°0: EMERGENCY / RESET
INPUTS
OPERATING FUNCTION N°0
MODE01 MODE02 MODE03
Emergency/reset
0 0 0
This operating function has two purposes:
1) Stop all turret movement (
EMERGENCY
).
2) Acknowledge all alarms, if they are present (
RESET
).
It must stay on for more than
30 ms
to be read by the control unit. It isn’t necessary to carry out a
RESET to go into or out operating function. In any case
, if a RESET is executed, it is necessary
to wait 800 ms before any variation of signals.
The INDEX signal goes low after a RESET.
The alarm output will be cleared changing from operating function N°0 to another operating
function (e.g. Automatic).
OPERATING FUNCTION N°1,2,3: AUTOMATIC
These operating functions are normally used to drive the turret.
Just set the code of the position required, give the start signal and the turret will automatically
reach the position.
1. Clear all alarms (if present);
2. Set an automatic function:
INPUTS
OPERATING FUNCTION N°1,2,3
MODE01 MODE02 MODE03
Automatic with shortest path search
1 0 0
Automatic CW
0 1 0
Automatic CCW
1 1 0
3. Set the position code: (use PBIT16 only for turrets with 16 tools or more).
POSITION
CODE
Zero
Cycle
1 2 3 4 5 6 7 8 9 10 11
12
PBIT01
0
1 0 1 0 1 0 1 0 1 0 1 0
PBIT02
0
0 1 1 0 0 1 1 0 0 1 1 0
PBIT04
0
0 0 0 1 1 1 1 0 0 0 0 1
PBIT08
0
0 0 0 0 0 0 0 1 1 1 1 1
(PBIT16)
0
0 0 0 0 0 0 0 0 0 0 0 0
PARITY
0
1 1 0 1 0 0 1 1 0 0 1 0
POSITION
CODE
13 14 15 16 17 18 19 20 21 22 23 24
PBIT01
1 0 1 0 1 0 1 0 1 0 1 0
PBIT02
0 1 1 0 0 1 1 0 0 1 1 0
PBIT04
1 1 1 0 0 0 0 1 1 1 1 0
PBIT08
1 1 1 0 0 0 0 0 0 0 0 1
(PBIT16)
0 0 0 1 1 1 1 1 1 1 1 1
PARITY
1 1 0 1 0 0 1 0 1 1 0 0
4. Set
PSTART
for give the confirmation of the movement within 5 s.
(It must stay ON for more than 30 ms).