61
C - Setup for Timers
To enter the timer setup menu, you will need to press and hold down both the “OPEN” and
“CLOSE” buttons, then turn the power on. You should see “SET TR” in the LED display.
Press the “FUNCTION” button to sequentially display TR1, TR2, TR3, TR4, TR5, TR6,
“SAVE”, “CANCEL”, and “RESET”. Once you have selected the setting to change, you
need to press the “OPEN” to increase the time and the “CLOSE” to decrease the time within
their ranges. Press “FUNCTION” button until you see “SAVE” in the LED display. Then
press the “START” button to change it. Or select “CANCEL” and press “START” button
to exit. To return all settings to default, please use “RESET” followed by “START” button
to recover the factory settings.
WARNING: We only recommend you to change TR1.
Below are the default times for each TRx and it’s description:
Name
Default Time
Range
Description
TR1
4 sec.
2.0 - 10 sec.
Nipping time.
TR2
1 sec.
0.5 - 5 sec.
Auto mode: After loading the
cover, the delay time before clamp
station returns.
TR3
2 sec.
1.0 - 5 sec.
Auto mode: Clamp closing time
for the book.
TR4
1 sec.
0.5 - 5 sec.
Auto mode: Clamp opening
time for the book.
TR5
.5 sec.
0.5 - 5 sec.
Auto mode: The clamp detecting
time right after closing.
TR6
5 sec.
3.0 - 10 sec.
Padding mode: The closing
time of clamp before opening it.
The fastest speed of settings that AUTO mode can perform is:
TR1 = 2 sec., TR2 = 0.5 sec., TR3 = 1 sec., TR4 = 0.5 sec., TR5 = 0.5 sec.
•
Note that the book making speed depends on thickness of the book and the loading
technique for the paper and cover.
Summary of Contents for DB-250
Page 2: ...PERFECT BINDER DB 250 SERVICE MANUAL SERVICE MANUAL Duplo USA Corp May 2000 Rev 2 6...
Page 32: ...28 4 Circuit Diagrams 4 1 Main Schematic Diagrams CPU TG200A1...
Page 33: ...29 CONTROL PANEL TG200B1...
Page 34: ...30 SSR TG200C2...
Page 35: ...31 FUSE BOARD TG200D2...
Page 42: ...38 4 Nipping Station Section...
Page 44: ...40 5 Clamp Station Section...