60
Check if the hot-melt
Yes
Thermostat has
ERR=T1
glue has been melted
been damaged.
completely ?
Change thermostat.
No
Check if the heater
No
Heater fuse has been
fuse is functioning OK ?
damaged.
Change heater fuse.
Yes
Heater has been
damaged.
Change heater.
Check if the heater
No
Heater fuse has
TEMP
fuse is functioning OK ?
been damaged.
ERROR
Change heater fuse.
Yes
Check if the heater
No
Heater has been
is functioning OK ?
damaged.
Change heater.
Yes
Check if thermostat
No
Thermostat has been
is functioning OK ?
damaged.
Change thermostat.
Yes
Check the heater
and related circuits.
Check if thermostat
No
TEMP2 sensor has
HALF00
is functioning OK ?
been damaged.
Change TEMP2.
Yes
Heater has been
damaged.
Change heater.