Technical Information
LVB
Page 9 of 12
Mounting Instructions for Light
Mounting Instructions for Light
Mounting Instructions for Light
Mounting Instructions for Light Grid Profiles
Grid Profiles
Grid Profiles
Grid Profiles
•
Disassembling of the plug components is not necessary.
•
Profiles must be off-circuit when connecting or disconnecting the power
supply.
•
Do not switch connections!
The light screen rods can be damaged if poles are switched.
Pay attention to the connector coding:
Plug components will only plug into the respective socket components!
•
The front panel must not be scratched. It must be kept free of obstacles and it
must be kept clean (do not use any cleaning agents containing solvents).
•
Use a test pin to check that the light grid is working in the entire monitoring
area.
•
It is generally not necessary to align the bars exactly. It
should nevertheless be possible to adjust the bars in specific
cases. The bars may also need to be moveable
longitudinally.
•
The monitored area between the transmitter and receiver
bars must be clear of obstructions so that the bars can “see”
each other.
•
Assemble with the power supply disconnected. Do not
expose the bars to stress.
•
Avoid ground loops: Bar pairs must have the same earth
potential.
•
Avoid the effects of external light sources (e.g., from
flashlights or sunlight) on the receiver.
•
Condensation, fog or smoke can impair the functioning of a
light grid.