Technical Information 

LVB 

 

Page 10 of 12

 

 

 

 
 

 

  Danger from reflective surfaces: Reflective surfaces in the 

area around the light curtain must be avoided. Otherwise 
obstructions will not be detected. 

 

 

 

 

 

  Avoid optical sensors from mutually affecting each other 

(e.g., other light curtains, light barriers) 

 

 

 

 

 

 

 

 
 

Important notes concerning usage and handling

Important notes concerning usage and handling

Important notes concerning usage and handling

Important notes concerning usage and handling    

  The light grids are not certified security light screens according 

to EN 61496. They are not safety components in accordance 
with EU machine guidelines 89/392/EWG with supplement 
93/44/EMW appendix 4. 
Therefore, they must not be used to protect individuals from 
danger. 

  Handling of the devices and connecting/disconnecting lines is 

only permitted with the operating voltage switched off. 

 
 

Conformity

Conformity

Conformity

Conformity    

Light grid systems consisting of wire-pair type LI and controller LVE carry the 

- stamp 

and meet the requirements of the following standards: 
 

  Emitted interference: EN 61000-6-3:2001. 

  Interference resistance: EN 61000-6-1:2001. 

 
 
 

 

 

 

 

 

 

Summary of Contents for LVB

Page 1: ...ble object recognition Increased safety safe shut down on contact bonding and no blanking of defect beams Floating relay contacts General description General description General description General description The device switches when one or more beams are interrupted The output relays have positively driven contacts 2xreverser each with one break contact lead back to a digital input That ensures ...

Page 2: ...4 Procedure 4 LED states during self calibration 4 LEDs 5 LED A 5 LED B 5 Fault LEDs 5 Special LED combinations 5 Initial operation 6 Circuit board view 7 LVB 7 LVB 24V 7 DIP Switch 8 Pin assignments LVB 24V 8 Connecting the profiles 8 Mounting Instructions for Light Grid Profiles 9 Important notes concerning usage and handling 10 Conformity 10 Technical data 11 Enclosure dimensions 12 ...

Page 3: ...nabled by parametrisation Auto blanking Auto blanking Auto blanking Auto blanking Interrupted beams are automatically blanked if the configuration value Auto blanking on cal is set to 1 Please notice that beams must be covered completely for the auto blanking procedure If beams are blanked LED A turns on Diagonal beams Diagonal beams Diagonal beams Diagonal beams With additional diagonal beams the...

Page 4: ...ted values to the EEPROM and turns back to normal operating mode If you don t want to store the new values turn off the supply voltage while the DIP switch 3 is still in position on LED states during self calibration LED states during self calibration LED states during self calibration LED states during self calibration LED Status D E Rx Tx on off off Self calibration o k off on off Could be accep...

Page 5: ...inated Warning Blanked beams watchdog LED B LED B LED B LED B Signal Status Even flashing approx 2 Hz Normal operation Continuously on or off serial communication crashed defective Fault LEDs Fault LEDs Fault LEDs Fault LEDs Signal Fault Signal Fault RX red illuminated Receiver TX red illuminated Transmitter RX TX illuminated Control unit Special LED combinations Special LED combinations Special L...

Page 6: ...r mounting the housing See housing diagram on page 12 2 Plug in the connectors of transmitter and receiver screw in the fittings loosely 3 Set DIP 3 to on for self calibration See page 4 4 Connect the relay contacts 5 Connect the power supply Set DIP 3 to off to complete self calibration 6 Verify that the light grid is working correct in the entire monitoring area 7 Screw the top on the housing in...

Page 7: ...Technical Information LVB Page 7 of 12 Circuit board view Circuit board view Circuit board view Circuit board view LVB LVB LVB LVB LVB LVB LVB LVB 24V 24V 24V 24V ...

Page 8: ...es are switched Pay attention to the connector coding Plug components will only plug into the respective socket components Profile connection wiring Detail Color assignments 2 Standard White Gray Yellow Brown Green Shielding Connector configuration of receiver bars for isolated mounting or with double shielding Profile connection wiring Detail Color assignments Standard White and Shielding Gray Ye...

Page 9: ...e kept free of obstacles and it must be kept clean do not use any cleaning agents containing solvents Use a test pin to check that the light grid is working in the entire monitoring area It is generally not necessary to align the bars exactly It should nevertheless be possible to adjust the bars in specific cases The bars may also need to be moveable longitudinally The monitored area between the t...

Page 10: ...and handling The light grids are not certified security light screens according to EN 61496 They are not safety components in accordance with EU machine guidelines 89 392 EWG with supplement 93 44 EMW appendix 4 Therefore they must not be used to protect individuals from danger Handling of the devices and connecting disconnecting lines is only permitted with the operating voltage switched off Conf...

Page 11: ...d Switching current min max 10mA 8 A Switching capacity min max 3 VA 2000 VA respectively 3 W 200 W Connectors Spring type terminal allowed wire cross sections min max in mm for static wires for flexible wires for flexible wires with wire end ferrule with and without plastic sleeve 0 2 1 5 0 2 1 0 25 0 75 Range with standard transmitter receiver 400 6000 mm Temperature 0 40 C Humidity up to 90 rel...

Page 12: ...Technical Information LVB Page 12 of 12 Enclosure Enclosure Enclosure Enclosure dimensions dimensions dimensions dimensions Dimensions in mm ...

Reviews: