81
SYMPTOMS
CAUSE
REFER TO
PAGE
2.Fan operated; compressor will not come on
(does not “hum).
(Cool or Heat Mode)
Mechanical Controls
Wiring
A3, C21
1, 58
Selector Switch
C9b
31
Mechanical Thermostat
C18a
42
Overload
C6
30
Compressor
C5
29
Bimetal Control System
Operation
B2b
24
Wiring
A3, C21
1, 58
Cable Assembly
C19
52
Bimetal Thermostat
C18a
42
Relays
C16
35
Relay Board
C17a
38
Overload
C6
30
Compressor
C5
29
Analog Control System
Operation
B2c
25
Wiring
A3. C21
1, 58
Fuse
C15
34
Breaker
A4
2
Analog Thermostat
C18d
50
Analog Control Box
C17b
39
Overload Protector
C6
30
Compressor
C5
29
Comfort Control Center System
Operation
B2d
26
Cable Assembly
C19
52
AC Power Module Board
C17d
40
Comfort Control Center
C18d
52
Overload
C6
30
Compressor
C5
29
3.Fan Operates; compressor tries to start, cycles
“OFF” and hums again, or blows circuit
breaker. (Cool or Heat Mode)
Mechanical Controls
AC Voltage
A1
1
PTCR or Start Relay
C4`
29
Start Capacitor
C3
28
Fan/Run Capacitor
C2
28
Overload
C6
30
Compressor
C5
29
Section E - Symptom/Cause Chart, cont’d.