Duke IRHU Series Owner'S Manual Download Page 10

Installation and Operation of IRHU

10

OPERATING INSTRUCTIONS

NOTE:

    Before  starting,  move  the  Power  Switch  to 

its OFF position then to its ON position.  All the lights 

should be RED.

NOTE:

  Always stand on the front side of the warmer 

facing the ON/OFF switch.

PROGRAMMING MODE

1.  Enter Programming Mode

 

Press and hold for 5 seconds the two keys closest 

to the ON/OFF switch.

 

One solid RED light will turn on. The two displays 

will show numbers. All other displays will go out.

Press both keys

Press both keys.

2.  Select and View Settings

 

The solid RED light indicates the selected pan.

 

The left display shows the setting number.

 

The right display shows the value.

   To change the setting number:

 

Press the arrow keys on the left display.

 

View the values on the right display:

Number

Value

RED Light

Selected Pan

Settings

  1 = Hold Time*

  7 = Phase 3 Time

  2 = Cook Time

  8 = Phase 3 %Heat

  3 = Phase 1 Time

  9 = Phase 4 Enabled

  4 = Phase 1 %Heat

10 = Linking

  5 = Phase 2 Time

11 = Copying

  6 = Phase 2 %Heat

*    READ  ONLY:  CALCULATED  INTERNALLY  BY 

ADDING PHASE HOLD TIMES

3.  Enter and Exit Edit Mode
 

To enter edit mode

 press and hold the DOWN arrow 

key for 3 seconds – the solid RED LED will blink.

 

To  exit  edit  mode

  press  and  hold  the  DOWN 

arrow key for 3 seconds – The blinking RED LED 

will turn solid.

4.  Edit Settings 1-8

 

Select the settings to be changed then enter edit 

mode. Use the UP DOWN arrow keys to change 

the value.

 

NOTE: FF = 

Phase at 100%

 

   

  9 = 

Phase 4 Enable/Disable

 

   

 

 

Enabled  = - -

 

   

 

 

Disabled = 00

 

Exit edit mode

5.  Edit Linking – Setting 10

 

Select  Setting  10,  then  enter  edit  mode. 

The  RED  light  indicates  the  selected  pan. 

The GREEN lights = Pans linked to the selected pan. 

The OFF lights = Pans not linked to the selected pan. 

 

Press any arrow key to turn the GREEN lights off. 

 

Exit edit mode.

6.  Copy – Settings 11:

 Copies the selected pan’s 

values to another pan.

 

Select setting 11, then enter edit mode. The blinking 

RED light indicates the selected pan.

 

The GREEN lights = pans that already have the 

same values.

 

The OFF lights = pans that have different values. 

 

To copy the selected pan, press any arrow key.  

 

The OFF light will turn YELLOW marking that pan 

to be copied. 

Summary of Contents for IRHU Series

Page 1: ...production without written permission is prohibited Duke is a registered trademark of the Duke Manufacturing Co Duke Manufacturing Co 2305 N Broadway St Louis MO 63102 Phone 314 231 1130 Toll Free 1 8...

Page 2: ...OTENTIAL EARTHING TERMINAL EXPORT ONLY 9 DIGITAL TIMERS 9 DIGITAL TIMER DISPLAYS 9 OPERATING INSTRUCTIONS 10 PROGRAMMING MODE 10 Settings 10 SETUP MODE 11 Settings 11 CARE AND CLEANING 12 CLEANING GUI...

Page 3: ...tastetransfer Becausethecompartments aresealed nodisassemblyisrequiredforcleaningand product changes The unique design of the Duke IR Holding Unit allows theIRenergytobeprogrammedforeachcompartment Th...

Page 4: ...gs and cautions appear throughout this manual and should be carefully observed Turn the unit off disconnect the power source and allow unit to cool down before performing any service or maintenance on...

Page 5: ...0 230 11 7 IRHU 22XXXX 240 240 11 3 IRHU 23XXXX 208 245lbs 111 Kg 208 19 5 4050 IRHU 23XXXX 230 230 17 6 IRHU 23XXXX 240 240 16 9 IRHU 41XXXX 208 175lbs 80 Kg 208 13 2700 IRHU 41XXXX 230 230 11 7 IRHU...

Page 6: ...7 8 835 03 mm 23 3 4 603 25 mm 15 380 31 mm 509L COOKING APPLIANCE DE CUISINE UNDERWRITERS LABORATORIES INC IN ACCORDANCE WITH NSF NO 4 1999 IHRU 23 Twist Lock Plug Schuko Plug 603 25 mm 1214 81 mm 12...

Page 7: ...U 41 Twist Lock Plug Schuko Plug 2 1 8 53 98 mm 2 1 2 63 89 mm 29 7 8 759 mm 17 7 8 454 96 mm 1 1 8 29 91 mm 23 5 8 601 40 mm 509L LISTED APPLIANCE DE CUISINE ALSO CLASSIFIED BY UNDERWRITERS LABORATOR...

Page 8: ...Stop Note the style of pan stop varies by model 5 4 IRHU 12 IRHU 22 IRHU 23 Rear View 4 Programming Connection Port 5 Power Cord with Strain Relief IRHU 41 FEATURES 1 2 3 IRHU 41 Front View 1 Power O...

Page 9: ...To avoid risk of electrical shock or death this unit must be grounded and plug must not be altered EARTHING INSTRUCTIONS Grounding reduces risk of electric shock by providing an escape wire for the el...

Page 10: ...ime 11 Copying 6 Phase 2 Heat READ ONLY CALCULATED INTERNALLY BY ADDING PHASE HOLD TIMES 3 Enter and Exit Edit Mode ToentereditmodepressandholdtheDOWNarrow key for 3 seconds the solid RED LED will bli...

Page 11: ...ge the setting number Press the arrow keys on the left display View the values on the right display Press both keys Settings Setting 99 Duty Cycle Length Do Not Change Factory set at 06 03 30 seconds...

Page 12: ...g towels may harm the unit 1 Turn unit off and allow cooling for 10 minutes 2 Removeallholdingpansandwash rinseandsanitize at the 3 compartment sink Allow to air dry 3 Spray a sanitizer soaked towel w...

Page 13: ...depending on the programmed hold times Troubleshooting Check that the Warmer control powers up and the Warmer heats up If not call Duke Mfg for Warmer service at 314 231 1130 or 800 735 3853 Service...

Page 14: ...6 12 12 12 18 18 18 8 159149 Block Terminal 2 Bar 8 Tab with fuse holder 1 1 1 9 159077 Relay Mini FS24D20 06 2 4 6 10 600143 600145 Kit IRHU Control Ver 13 Kit IRHU Control Ver 16 1 1 1 1 1 1 11 159...

Page 15: ...15 Installation and Operation of IRHU 11 2 3 4 16 25 15 20 21 10 7 5 1 18 12 14 17 23 22 9 8 13 IHRU 22 Exploded View...

Page 16: ...12 12 8 159149 Block Terminal 2 Bar 8 Tab with fuse holder 1 9 159077 Relay Mini FS24D20 06 4 10 600143 600145 Kit IRHU Control Ver 13 Kit IRHU Control Ver 16 1 1 11 159080 Current Sensor with Connec...

Page 17: ...17 Installation and Operation of IRHU IHRU 41 Exploded View 13 12 18 16 15 7 3 4 24 17 23 2 14 8 9 22 20 21 10 1 5...

Page 18: ...Installation and Operation of IRHU 18 WIRING DIAGRAMS DUKE INFRARED HOLDING UNIT MODEL IRHU 12 208 240 VAC 50 60 HZ 1 PH...

Page 19: ...19 Installation and Operation of IRHU DUKE INFRARED HOLDING UNIT MODEL IRHU 22 208 230 240 VAC 50 60 HZ 1 PH...

Page 20: ...Installation and Operation of IRHU 20 DUKE INFRARED HOLDING UNIT MODEL IRHU 23 208 230 240 VAC 50 60 HZ 1 PH...

Page 21: ...21 Installation and Operation of IRHU DUKE INFRARED HOLDING UNIT MODEL IRHU 41 208 230 240 VAC 50 60 HZ 1 PH...

Page 22: ...SERVICE DUKE EMEA UK IRELAND NORDIC COUNTRIES Duke Manufacturing UK Ltd Unit 10 Greendale Business Park Woodbury Salterton Exeter EX5 1EW Phone 44 0 1395 234140 Fax 44 0 1395 234154 service exeter duk...

Page 23: ...23 Installation and Operation of IRHU NOTES...

Page 24: ...2 Jazlovice Ricany Building number DC 4 on the ProLogis Park Prague D1 West Prague 251 01 Czech Republic Phone 420 257 741 033 Fax 420 257 741 039 Duke EMEA UK Ireland Nordic Countries Duke Manufactur...

Reviews: