16
184662
DUKE Model 957R Soft Serve Freezer
Figure 6-8
Figure 6-9
Replace worn brushes. Use
only original or authorized
replacement parts. See Ac-
cessories Parts list in Part II
of this manual to order new
brushes.
6.3 Cleaning - continued
3.
After all parts are washed, rinse
and then place them in the sani-
tizer solution. For proper sanitizing,
the parts must remain fully im-
mersed in the sanitizer for 5
minutes. Allow parts to air-dry after
sanitizing.
4.
Use the sanitizing solution and
brush to thoroughly brush the mix
feed tubes, from the top of the
tubes to the cylinders as shown in
figure 6-8. Also, brush both ends of
the mix feed hose.
5.
Brush the inside of the cylinders,
making certain to clean back walls.
6.
Brush the inside of the drain tube,
as shown in figure 6-9. Dip the
brush in clean water and force into
the tube until it stops. Repeat until
clean.