Section 3 – Standard Connections
Dukane Manual Part No. 403-610-02
This section provides an overview of the generator rear
panel layout, which includes panel areas dedicated to
various standard system functions and options that are
available. Figure
3 - 1
illustrates the panel layout.
Bottom Panel Layout Overview
Chassis Grounding Stud
The chassis grounding stud is used to attach a protec-
tive earth ground to the generator. This will aid in the
suppression of electrical interference or radio frequency
interference (RFI) that is common in an industrial envi-
ronment. The chassis ground stud is
C
in Figure 3-1.
Proper system grounding is discussed in
Section 2
.
AC Power Inlet Panel
The standard AC power inlet panel is described in this
section.
Figure 3 - 1
Generator Bottom Panel
G
ETHERNET/IP / MODBUS TCP/IP
F
USB
E
ULTRASOUND
A
AC POWER ENTRY
C
PE
B
AC BREAKER
H
MPC
I
ANYBUS OPTIONS SLOT
D
SYSTEM I/O
A
IEC Power Inlet Connector – Attaches to an IEC
stylepower cord.
B
Power Switch – Circuit Breaker – Used to switch sys-
tem power ON and OFF.
C
Chassis Grounding Stud – Chassis connection for a
protective earth ground.
D
System Input/Output Connector – Connections for
system control input signals and system status output
signals.
E
Ultrasound Output Connector – Coaxial high voltage
connection to ultrasonic stack.
F
Configuration Port Connector – Digital control port to
modify system parameters.
G
EtherNet/IP Connector – Provides for communication
between the
iQ
generator and an
automation network.
H
Multi-Point Control Connector - Used to connect an
MPC module.
I
An option module can be installed here.