Page 34
iQ Series AiM
™
Automation in Mind
,
Ultrasonic Power Supply User’s Manual
Dukane Manual Part No. 403-610-02
Setup
Identification
Setup identification can be seen at the top of the screen
as shown in the figure below.
The example shown in Figure 4-9 illustrates that setup
control is by the front panel interface or an industrial
network such as Ethernet/IP.
Figure 4-9
Main Menu Detail - Setup Identification
This is the name of the setup
being edited if in Automation
mode. Otherwise, the setup
shown is the one in use.
If
01
is displayed, this indicates that the setup selection
is controlled by generator. If
A01
is displayed, setup
selection is controlled by automation.
Continued
The Status Bar
U/S STATUS: U/S Indicates Ultrasound status. If it is a
gray ultrasound is off. Orange means ultrasound is on
and blinking red that the ultrasound output is greater than
90% of the rated power of generator based on the current
amplitude setting.
PART STATUS:
G shows the part status of the last weld
cycle. Gray means a weld cycle hasn’t run since the
generator was powered up. Green indicates a good part,
yellow a suspect part, and blue a bad part.
PLC CONNECTION:
PLC indicates if a PLC is con-
nected. Green means a PLC is connected to the genera-
tor. Otherwise PLC is gray.
AMPLITUDE CONTROL:
R indicates how the ampli-
tude is controlled. If it is gray the generator controls the
amplitude, green means amplitude is controlled by the
analog input and if “OTF” is displayed a PLC controls
amplitude.
NETWORK STATUS:
When NET is green a network is
connected at 100Mbps. When orange, a network is con-
nected at 10Mbps. When gray, no network connected is
detected.
SETUP CONTROL:
If the # symbol is the leading char-
acter, the setup selection is controlled by the generator
(#01 for example). If the leading character is A the setup
selection is controlled automation.
GENERATOR STATUS:
When Online is displayed, the
generator is capable of outputting ultrasound. If Offline
is shown, the offline key has been pressed to disable ul
-
trasound. E-STOP indicated ultrasound output is disabled
due to the E-STOP signals on the I/O connector.
MPC CONTROL:
If an MPC is connected the selected
probe is displayed here. For example, P08 indicates that
MPC Probe 8 is selected by the generator. This is useful
for checking the generator to MPC wiring if the cable
that connects them together has been modified.