Approved 2 pole, 3 wire grounding
receptacle HUBBELL No. 5652 or
equivalent to NEMA 6–15R or 6–20R
Figure 1–1
Example of 220/240 Volt,
Grounded, 3-Prong Receptacle
Electrical Safety
Domestic Power Grounding
For safety, the power cords used on this product have a
three-wire, grounding-type power cord. Figure 1-1 il-
lustrates the appropriate electrical outlet to use with the
power cord that is included with systems shipped to North
America.
International Power Grounding
The power cable normally provided for international use is
compatible with the power outlet used in many Continen-
tal European countries (Refer to Figure 1–2). However,
if your application requires another type of power cord,
check with your equipment supplier, and follow local reg-
ulations concerning proper wiring and grounding.
Grounding Contacts
Typical Outlet
Provided Cable
Figure 1-2
International 220/240V Grounding
CAUTION
If you have a two-prong elec-
trical receptacle, we strongly
recommend that you replace
it with a properly grounded
three-prong type. Have a
qualified electrician replace it
following the National Electric
Code and any local codes
and ordinances that apply.
See Figures 1-1 and 1-2.
If there is any question about
the grounding of your recep-
tacle, have it checked by a
qualified electrician. Do not
cut off the power cord ground-
ing prong, or alter the plug in
any way. If an extension cord
is needed, use a three-wire
cord that is in good condition.
The cord should have an ad-
equate power rating to do the
job safely. It must be plugged
into a grounded receptacle.
Do not use a two-wire exten
-
sion cord with this product.
CAUTION
Short-Circuit Current Rating
The SCCR (Short-Circuit Current Rating) value is the
maximum short-circuit current an electrical component
can safely withstand without causing a shock or fire
hazard. For integration into an electrical control panel/
cabinet, some customers require the generator SCCR
rating. The iQ generator include a AC line circuit breaker
that has a SCCR rating as indicated below.
For generators rated between 700-2600 watts of output
power, the SCCR rating is 250 Amps. For generators rated
3600 watts and above, the SCCR rating is 1500 Amps.
Continued from Previous Page