background image

Contatto

ModDMX

ModDMX: DMX gateway

ModDMX module allows to handle, through the  

Contatto 

bus, up to 32 DMX devices. ModDMX module makes pos-
sible the communication on the first 64 of 512 DMX chan-
nels allowed by this protocol.
ModDMX module can be successfully employed in profes-
sional  and  domestic  lighting  applications,   where   systems 
communicating by the USITT DMX-512 protocol are used, 
as theaters, disco clubs, architectural lighting, etc.

ModDMX module features the following characteristics:

all functions are managed by the module and can be 
controlled by any real or virtual input of the system, by 
supervisor or by video-terminal

possibility to control the DMX system from one or more 
pushbuttons connected to the 

Contatto

 bus

up to 64 sceneries are available to realize “real time” 
scenes;   the  sceneries   are  stored  in   the  non  volatile 
memory of the module

management of fade times

management of different rooms by the same ModDMX

The module can manage up to 64 DMX channels, but the 
total amount of connected DMX devices may be lower than 
64 if the device gets more than one channel. Moreover, the 
total amount of connected DMX devices may be anyway 
lower than 32. ModDMX module can operate exclusively in 
system   using   MCP   XT   controller.   Up,   Down   and   Single 
Command function, with or without one-touch feature, can 
be performed by the module from any real or virtual input of 
the system (see in the following of this manual); in addition, 
it is possible to save and recall the sceneries.

The module features a removable 5-way terminal block for 
the connection to the  Contatto  bus and a fixed 3-way ter-
minal block for the DMX line. A green LED near to the bus 
terminal block shows that the module is supplied, while a 
yellow   LED   near   to   the   3-way   terminal  block   shows   the 
presence of communication on the DMX line.  ModDMX is 
housed in a standard DIN 3M box for rail mounting.

Note: this manual applies to ModDMX modules equipped by  
firmware version 2.2 or higher.

Address programming

ModDMX module takes 1 output address, 1-channel 16-bit. 
The address must be assigned by FXPRO programmer. A 
white label on the front panel allows the writing of the as-
signed address for an immediate visual identification.

Wiring diagram

The following schematic diagram shows the connection to 
be made between ModDMX module, the 

Contatto

 bus and 

the DMX line, using proper cables as described in the re-
lated table.
Generally, the DMX devices feature a female XLR 5-way or 
3-way   connector,   therefore   in   this   case   the   cable   of 
ModDMX must be properly wired to a male XLR connector 
(not provided) according to the specification of the manu-
facturer of the device.

Even if the standard specifies a maximum of 32 devices for 
the DMX line, as a good rule do not override a total amount 
of 16-20 devices. If the number of devices is higher than 
20, use proper line splitters to connect the devices overrid-
ing this limit.

DUEMMEGI

ADDRESS

Contatto

MILANO-ITALY

DMX Gateway 

Power supply                  24V=  ±25% / 50mA

MODDMX

ON

+2

4V

0V

L1

L2

P

13 14

16 17

15

+24V

BUS

0V

L1

L2

1

2

3

A

 (+)

B

 (-

)

G

DMX

TX

  

  

XLR

The following table provides some suggestions about the 
cables to be used for the connections and the related max-
imum length.

Connection

Suggested cable

Contatto

 bus

4 x 2.5 mmq MAX not shielded, 
MAX 1.5Km

DMX line

2 twisted pairs 2 x AWG22 MIN
(e.g.: Belden 3107A or 9841 or 
CEAM CPR6003), MAX 1Km

DUEMMEGI

 s.r.l. - Via Longhena, 4 - 20139 MILANO

Tel. 02/57300377 - Fax 02/55213686 – 

www.duemmegi.it

Rel.: 2.2 December 2013

Page 1 of 7

HOME AND BUILDING AUTOMATION

Summary of Contents for Contatto ModDMX

Page 1: ...o the bus terminal block shows that the module is supplied while a yellow LED near to the 3 way terminal block shows the presence of communication on the DMX line ModDMX is housed in a standard DIN 3M...

Page 2: ...aved if the low byte is 0 then all channels will be included 103 0x67 Exclude the channel specified by the low byte in the next scenery that will be saved if the low byte is 0 then all channel will be...

Page 3: ...ng Up Down pushbuttons pushing and holding Up Down button the brightness increases decreases until the max min value is reached When the brightness has reached the desired level release the button to...

Page 4: ...es Set minimum and maximum value The commands 135 and 136 0x87 and 0x88 allow to set a minimum and a maximum value on all DMX channel for the functions Up Down and Single Command Broadcast command The...

Page 5: ...hannel and to the following two The just seen RGB assignment allows to easily set on the RGB spot the desired color chosen on the color palette that will be opened by clicking on the colored square un...

Page 6: ...ModDMX which is communicating with MCP Ide Code is the value of the code to be sent to to ModDMX module high byte of the Word to be sent see the bus com mand table Val Sc Ch is the value or the scene...

Page 7: ...e Contatto bus line and the re lated devices must be performed according to the recommenda tions of the manufacturers reported on the specific data sheet of the product and according to the applicable...

Reviews: