21
11) FINAL POSITION OF THE LIMIT SWITCH MAGNETS
To identify the final fixing position of the limit switches, open the opening and closing
cycles, taking care to move the magnets a few centimeters at a time, bringing them
closer and closer to their final position.
In this way it will be possible to perfectly fit the magnets. Check that the gate stops
correctly in the desired position, both in opening and closing.
WARNING
: It is absolutely necessary to pay maximum attention to the correct posi-
tioning of the limit switch magnets. Check that the gate does not protrude from the
magnet striking the mechanical stop.
Basic installation is complete!
Follow the instructions for connecting accessories and adjustments corresponding to
the engine model.
12) ELECTRICAL CONNECTIONS:
See the connection diagrams corresponding to your electronic board model on the
following pages.
How to memorize a remote control:
Attention, check that:
- The gate must be closed on the limit switch magnet. Check that the yellow LED on
the electronic board is on.
- Check that the gate is in "step by step" operating mode = "TIME" potentiometer tur-
ned anticlockwise to position = zero.
- Check that the motor power is set to maximum. = "POWER" potentiometer comple-
tely turned timeless.
See diagram 14 for the CTH46 board and diagram 16 for the CTH43V / 24 board.
Each button on the remote control corresponds to a broadcast channel. The button to
be used to control the motor must be stored in the memory of the motorization electro-
nic board.
10.1) REMOTE CONTROL MEMORIZATION
(see also the remote controls chapter).
- On the electronic board, press the P1 key.
- The red LED light turns on.
- Release the P1 key.
- Press the remote control button (hold it down for a few seconds) that you have cho-
sen to control the performance.
- The red LED on the electronic board flashes briefly to confirm storing the code.
- Procedure completed.
10.2) FIRST OPERATION:
- Unhook the gate and manually position it halfway (the gate must be positioned hal-
fway between the magnet of the two limit switches).
- Close the gate again.
- Press the button of the previously memorized remote control.
- Wait for the portal to perform the first one manually.
- Check that the gate stops as soon as it intercepts the limit switch and that the yellow
LED lights up.
WARNING:
If the gate does not stop at the limit switch magnet, the gate will lock into
the mechanical stop of the frame. The mechanical stop will be identified as an obsta-
cle.
It will be necessary to correct the position of the motor by reducing the distance from
the motor to the rack so that the magnet is correctly detected by the electronic board
(and then the yellow LED lights up to confirm it).
DUCATI