22
ENGLISH
11) E
LECTRICAL
AND
MECHANICAL
SPECIFICATIONS
Dimensions and weight
: 88 x 127 x 58 mm – 0,3 Kg
Mains power supply
: 230 Vac +/- 10%
Operating temperature range
: 0 to + 60 °C
Single-phase motor power supply
: 230 Vac 1 HP max
Motor’s work time
: programmable, 1 to 250 sec.
Operating frequency
: 433,92 MHz
Radio receiver RF sensitivity
: approx. -102 dBm
Caution
: The unit must be not switched on if the connected loads or the power supply
exceed the a.m. limits. Failure to observe this precaution can result in damage to
persons, animals or objects for which the manufacturer cannot be held responsible.
12) E
LECTRIC
CONNECTIONS
2 electric connectors are fitted to the card :
a) J1
5-pole Terminal board for the connection of the devices operating with 230 Vac mains
power supply (motor and mains cable).
b) J2
5-pole Terminal board for the connection of the devices operating at low voltage
(commands and aerial).
T
ERMINAL
BOARD
J1
Terminal 1 -
230 Vac mains power supply phase
Terminal 2 -
230 Vac mains power supply neutral
Warning: The power supply voltage polarities must be carefully observed.