![Ducasa GKH12K3CI Installation Manual Download Page 54](http://html1.mh-extra.com/html/ducasa/gkh12k3ci/gkh12k3ci_installation-manual_2537507054.webp)
A/A DC INVERTER U-MATCH AIR CONDITIONERS INSTALLATION
86
2.4 Dimension Data
Figure3-17 Unit
:
mm
Model
tem
GUHD12NK3CO
GUHD18NK3CO
GUHD24NK3CO
GUHD30NK3CO
GUHD36NK3CO
GUHD36NM3CO
GUHD42NK3CO
GUHD42NM3CO
A 776 955 980 1107
B 320 396 427 440
C 540 700 790 1100
D 510 560 610 631
E 286 360 395 400
2.5 Installation Clearance Data
Figure 2-5-1
3 REFRIGERATION PIPING WORK
3.1 Refrigeration Piping Work Procedures
1
)
Connection Pipe
The connection pipe must meet the following requirements. The three basic principles are that the pipe shall be
kept dry, clean and no leakage
.