Ducasa Colorado DGi+ Manual Download Page 8

8

Wednesday

11:00

21

.5°C

Wed. 11:00

Set point:

COMFORT

Wed. 11:00h

21

.5°C

Set point:

21

.5°C

Wed. 11:00

Set point:

COMFORT

If you don’t have the access to the 

 

 App or are unable to pair using the method 

above , press the Link button on the Gateway 

3

 

for 3 seconds.

Once the orange LED starts to flash, press the 

CONFIG button on the Colorado DGi+ and press 

the +/- button until the RF icon 

flashes. Then press OK

‘Link’ together with an antenna 

icon will appear in the top right 

of the screen.

Your  Colorado  DGi+  is  now 

connected to the 

 

 Gateway.

Please Note

:  Once  the 

 

 

Gateway’s  link  button  is  pressed  you  have  one 

minute  to  add  a  heater.  When  the  heater  has 

been added, you have one minute to add a further 
heater without pressing button 

3

GEOLOCATION

This  mode  allows  your 

 

system to reduce the set temperature by a number 

of degrees that is configured for each device from 

the  App  when  you  are  away  from  home.  The 

default is 2 degrees.

Geolocation is activated from the 

  

 App within the Homes setting. If activated, 

all  connected 

 

  devices  in 

the house will use this feature and AWAY will be 

shown on the Colorado DGi+ display.

If  any  button  is  pressed 

on 

any 

connected 

 

 

device, all 

  devices  in  the 

house will exit Geolocation 

mode  for  2  hours,  unless 

it’s turned back on again.

USING WITHOUT SMARTCOMMAND TEVOLVE APP

USING IN OPERATING MODES 

To  assist  with  the  operation  of  the  Colorado 

DGi+,  the  TFT  screen  is  backlit  and  will  stay 

illuminated for approximately 10 seconds after the 

last  button  is  pressed.  (To  change  the  backlight 

duration, see the section on DISPLAY)

When the towel rail is operational and the room 

temperature is lower than the set temperature the 

heating  symbol    will  be  shown  indicating  that 

the towel rail is producing heat. 

The  following  screens  show 

MANUAL

AUTO

 

and 

OFF

 modes.

To  scroll  between 

MANUAL

  and 

AUTO

  press

 

Mode/OK

 button. 

To enter and exit 

OFF

 mode press the 

ON/OFF 

button. When 

OFF

 mode is exited, it returns to the 

mode used prior to entering 

OFF

 mode.

When  the  towel  rail  is  in 

MANUAL

  mode  the 

temperature can be adjusted by pressing the +/- 

button. The towel rail will regulate the room to the 

chosen set temperature.

When  the  towel  rail  is  in 

AUTO

  mode  the 

temperature can be adjusted by pressing the +/- 

buttons. This change will remain active until either 

the next programme change or until midnight when 

the temperature will revert to the preset value.

When  the  temperature  has  been  adjusted  in 

AUTO mode a hand will show beside the auto to 

symbol to show the amended set-point. 

To  return  to AUTO  mode  press  the

 Mode/OK 

button.

NOTE:

 To rapidly change the temperature set-

point in any mode press and hold the +/- button.

orange

green

Summary of Contents for Colorado DGi+

Page 1: ...E1400298 20220110 NOTE A qualified electrician must carry out the electrical installation of this towel rail The electrical installation must comply with current UK regulations Any claim on the warra...

Page 2: ...P 7 Connecting to the smart command tevolve app 7 Geolocation 8 USING WITHOUT SMARTCOMMAND TEVOLVE APP 8 Using in operating modes 8 Setting the time and date 9 Entering a program 9 Set program tempera...

Page 3: ...young children it is recommended to install this towel heater so that the lowest heating bar is at least 600 mm above the floor This appliance must only be installed according to this installation man...

Page 4: ...QR code to access to the download It is also possible to programme each towel rail individually without theApp by using the built in controls and screen This may be convenient for single heaters howe...

Page 5: ...tches and other control devices can be touched by a person in the bathtub or shower This product is rated as IP44 and can be located in zone 2 the area stretching 60cm outside the perimeter of the bat...

Page 6: ...etween the 2nd and 3rd horizontal tubes from the bottom STEP 1 First the 4 supports are placed on the towel rail take a piece B fix the piece D with the screw C and insert it between two tubes from th...

Page 7: ...u must first connect and register your Gateway To do this follow the instructions in the gateway manual Ensure you have downloaded and logged into the App using your user name and password then press...

Page 8: ...nless it s turned back on again USING WITHOUT SMARTCOMMAND TEVOLVE APP USING IN OPERATING MODES To assist with the operation of the Colorado DGi the TFT screen is backlit and will stay illuminated for...

Page 9: ...ting the time To exit the Date function press the CONFIG button To turn Daylight savings on or off select the DST function from within the time settings and then use the button to cycle the function O...

Page 10: ...s shown at the bottom of the screen The screen will alternate between the current programmed temperature mode and the next programmed Comfort Economy ON time At any time the temperature can be tempora...

Page 11: ...w a coloured bar across the bottom of the screen to encourage the user to set an economical temperature This feature is turned on and off in the ECO DISPLAY menu To de activate the beep when each key...

Page 12: ...owel rail will restore normal function in any of these situations After 30 minutes If the temperature increases by 0 2 C for 1 minute from the point of activation Pressing any key on the Heater By def...

Page 13: ...assword is turned off the Keylock Advanced Settings menu and Runback controls are accessible without entering a password The first press of any button will wake up the towel rail any further button pr...

Page 14: ...os for each of the settings When Setback and Max temp is OFF the user has a choice between the minimum towel rail temperature of 7 C and the Runback temp setting Outside of the Runback period the temp...

Page 15: ...rail continuously checks to ensure that it is working correctly all the time however in some cases the towel rail may display an Error code on the screen Below you will find each code and a short desc...

Page 16: ...t mode temperature 21 C Boost mode time 1 hour Low Surface Temperature Disabled Password status Activated Password 0000 Units C Keyboard Unlocked Easy mode Disabled Runback mode Disabled Setback Disab...

Page 17: ...elmax 0 0005 kW 0 0005 kW At minimum heat output elmin 0 0005 kW 0 0005 kW In standby mode elSB 0 0005 kW 0 0005 kW Type of heat output room temperature control Electronic room temperature control pl...

Page 18: ...18 NOTES...

Page 19: ...19 NOTES...

Page 20: ...posed of with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types o...

Reviews: