DualLite LG125R Installation Instructions And User Manual Download Page 7

7

104.5 Recessed Wall Mount Model (LG125R):

1)  Remove cover and any packing material inside unit 

housing that may have been used for shipping purposes.

2)  For ease of  installation, and to prevent possible damage 

to the equipment, the inverter/charger assembly may 

be temporarily removed prior to knockout removal and 

attachment to mounting surface. This is accomplished 

by removing (4) 8-32 hex nuts on the inverter/charger 

mounting plate. If shipped factory installed, batteries 

may also be temporarily removed to facilitate ease of 

installation.

3)  Remove the appropriate  knockouts, 7/8” diameter, on 

the top and/or left side of the unit housing to facilitate 

conduit attachment. Also remove the appropriate round 

knockouts, 5/16” diameter, which are located on all 

sides of unit housing. Specific knockout requirements 

are dictated by mounting orientation of unit (vertical or 

horizontal) and location of wall studs and /or other support members.

4)  Secure housing to support members through round knockouts using mounting hardware (not supplied) sized 

appropriately to support the unit weight. 

IMPORTANT: Unit should be so positioned that the cabinet extends between 3/8” and 3/4” beyond the finished 

wall surface after installation.

5)  Prior to final attachment of unit cover, the LED indicator panel assembly position must be adjusted to sit flush against 

inside surface of cover after attachment. This is accomplished using the (2) 8-32 hex nuts on the indicator assembly.

6)  Re-install inverter/charger assembly if removed in step 2.

104.6 Recessed Ceiling T-Grid Mount Model (LG125T):

1)  Remove cover and any packing material inside unit hous-

ing that may have been used for shipping purposes.

2)  For ease of installation, and to prevent possible damage 

to the equipment, the inverter/charger assembly may 

be temporarily removed prior to knockout removal and 

attachment to mounting surface. This is accomplished by 

removing (4) 8-32 hex nuts on the inverter/charger mount-

ing plate. If shipped factory installed, batteries may also 

be temporarily removed to facilitate ease of installation.

3)  Remove the appropriate knockout(s), 7/8” diameter, located on either side of unit housing to facilitate conduit 

attachment. 

IMPORTANT: Take care to remove only the knockouts required for utility connection. Removal of knockouts 

if unused and left open will void the plenum rating of the unit.

4)  Mount the unit securely in place between T-Grid members. 

NOTICE: Safety chain or cable, rated 50lb minimum working load, 250lb minimum breaking strength is 

required to hang the unit in a T-Grid system. Failure to correctly install unit will cause an unsafe condition!

5)  Re-install inverter/charger assembly if removed in step 2.

Summary of Contents for LG125R

Page 1: ...r 125VA 110W 250VA 220W Mini Inverter Power Systems Models LG125S Surface Mounted Version LG125R Recessed Wall Mounted Version LG125T Recessed Ceiling T Grid Mounted Version LG250S Surface Mounted Ver...

Page 2: ...uipment should be mounted in locations where it will not be readily subjected to tampering by unauthorized personnel 7 The use of accessory equipment not recommended by the manufacturer may cause an u...

Page 3: ...Output Connections 8 Wiring Diagram 1 120VAC Connections 9 Wiring Diagram 2 277VAC Connections 9 106 Battery Information 10 106 1 Tools 10 106 2 Battery Installation and Connections 10 Wiring Diagram...

Page 4: ...solator Standard battery Sealed lead calcium 10 year life Battery voltage 24 or 48 system dependent See Table 1 below Runtimes 90 minutes standard Operating temperature 20 C to 30 C 68 F to 86 F Relat...

Page 5: ...ent caps and into the air Do not allow smoking sparks or flames in battery storage location because hydrogen is concentrated under the vent cap of each cell of the battery Hydrogen is highly explosive...

Page 6: ...its and damage the equipment NOTE Consider unit knockout locations prior to mounting unit Allow room for easy routing of conduit to entry point 104 4 Surface Mount Models LG125S LG250S and LG250SI 1 R...

Page 7: ...ent of unit cover the LED indicator panel assembly position must be adjusted to sit flush against inside surface of cover after attachment This is accomplished using the 2 8 32 hex nuts on the indicat...

Page 8: ...Switch S2 is in the OFF position 2 Make sure the LG inverter system input and output voltages are correct for the particular application Remember that the LG system provides single phase power only 3...

Page 9: ...77V wiring Normally On and Normally Off Operation A combination of the operating modes described above See C in Wiring Diagram 1 for 120V wiring or G in Wiring Diagram 2 for 277V wiring Switched Load...

Page 10: ...void electric shock and burns caused by contacting battery terminals or shorting terminals during battery installation Do not touch uninsulated battery terminals 8 A qualified electrician who is famil...

Page 11: ...rrect polarity on the battery terminals Polarity markings may vary from battery to battery Battery Wiring Diagram 1 Battery Wiring Diagram 2 Battery Wiring Diagram 3 106 3 Battery Connection Voltage C...

Page 12: ...en to follow the steps below in their exact sequence Failure to do so may result in possible equipment failure CAUTION Familiarize yourself with the shut down procedure in Section 200 1 before proceed...

Page 13: ...s a service alert Refer to the INDICATION chart in Section 110 2 for details During loss of normal utility power the dual color LED will not be illuminated The AMBER INV ON LED indicator will be illum...

Page 14: ...ded if not routinely recharged NOTE To turn power back on follow the System Start up Procedure outlined in Section 108 Be sure to complete all of the steps to assure the unit will operate properly 200...

Page 15: ...stem and to maintain proper charger operation replace spent batteries only with cells having the same part number voltage and ampere hour rating as the original batteries 1 Follow the proper shut down...

Page 16: ...Hubbell Lighting Inc brand with representatives offices in principal cities throughout North America Copyright Hubbell Lighitng Inc All Rights Reserved Specifications subject to change without notice...